Miller Electric HF-251D-1, HF-251-2 Principal Safety Standards, EMF Information, About Pacemakers

Page 8

1-5. Principal Safety Standards

Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1, from American Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126 (phone: 305-443-9353, website: www.aws.org).

Recommended Safe Practices for the Preparation for Welding and Cut- ting of Containers and Piping, American Welding Society Standard AWS F4.1, from American Welding Society, 550 N.W. LeJeune Rd, Mi- ami, FL 33126 (phone: 305-443-9353, website: www.aws.org).

National Electrical Code, NFPA Standard 70, from National Fire Protec- tion Association, P.O. Box 9101, 1 Battery March Park, Quincy, MA 02269−9101 (phone: 617−770−3000, website: www.nfpa.org and www. sparky.org).

Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1, from Compressed Gas Association, 1735 Jefferson Davis Highway, Suite 1004, Arlington, VA 22202−4102 (phone: 703−412−0900, web- site: www.cganet.com).

Code for Safety in Welding and Cutting, CSA Standard W117.2, from Canadian Standards Association, Standards Sales, 178 Rexdale

Boulevard, Rexdale, Ontario, Canada M9W 1R3 (phone: 800−463−6727 or in Toronto 416−747−4044, website: www.csa−in- ternational.org).

Practice For Occupational And Educational Eye And Face Protection, ANSI Standard Z87.1, from American National Standards Institute, 11 West 42nd Street, New York, NY 10036−8002 (phone: 212−642−4900, website: www.ansi.org).

Standard for Fire Prevention During Welding, Cutting, and Other Hot Work, NFPA Standard 51B, from National Fire Protection Association, P.O. Box 9101, 1 Battery March Park, Quincy, MA 02269−9101 (phone: 617−770−3000, website: www.nfpa.org and www. sparky.org).

OSHA, Occupational Safety and Health Standards for General Indus- try, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q, and Part 1926, Subpart J, from U.S. Government Printing Office, Super- intendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250 (there are 10 Regional Offices−−phone for Region 5, Chicago, is 312−353−2220, website: www.osha.gov).

1-6. EMF Information

Considerations About Welding And The Effects Of Low Frequency Electric And Magnetic Fields

Welding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields. However, after examining more than 500 studies spanning 17 years of research, a special blue ribbon committee of the National Research Council concluded that: “The body of evidence, in the committee’s judgment, has not demonstrated that exposure to power- frequency electric and magnetic fields is a human-health hazard.” However, studies are still going forth and evidence continues to be examined. Until the final conclusions of the research are reached, you may wish to minimize your exposure to electromagnetic fields when welding or cutting.

To reduce magnetic fields in the workplace, use the following procedures:

1.Keep cables close together by twisting or taping them.

2.Arrange cables to one side and away from the operator.

3.Do not coil or drape cables around your body.

4.Keep welding power source and cables as far away from opera- tor as practical.

5.Connect work clamp to workpiece as close to the weld as possi- ble.

About Pacemakers:

Pacemaker wearers consult your doctor first. If cleared by your doctor, then following the above procedures is recommended.

OM-611 Page 4

Return To Table Of Contents

Image 8 Contents
Description OM-611Processes From Miller to You Table of Contents Page Symbol Usage Marks a special safety messageArc Welding Hazards Electric Shock can killARC Rays can burn eyes and skin Welding can cause fire or explosionFlying Metal can injure eyes Buildup of GAS can injure or killCalifornia Proposition 65 Warnings About Pacemakers Principal Safety StandardsEMF Information Identifie un message de sécurité particulier − Consignes DE Sécurité − À Lire Avant UtilisationLE Soudage peut causer un incen- die ou une explosion LES Particules Projetées peu- vent blesser les yeuxLES Pièces Chaudes peuvent cau- ser des brûlures graves LE Bruit peut affecter l’ouïeRisque D’INCENDIE OU D’EXPLO LA Chute DE L’APPAREIL peut blesser’EMPLOI Excessif peut Faire LES Pièces Mobiles peuvent cau- ser des blessuresConsignes relatives aux stimulateurs cardiaques Principales normes de sécuritéInformation sur les champs électromagnétiques Typical Process Connections − InstallationSpecifications Installing Gas Supply IN-GAS-OUTPower Source Plug Information And Connections Amperage ControlSocket Operator Control Receptacle Information And ConnectionsOperator Control Receptacle Socket Information Connecting To Weld Output Terminals Electrode Electrode OUT Work INPUT/OUTPUTConnecting Input Power High Frequency Switch High Frequency Selector Switch− Operation ControlsPower Switch And Pilot Light Postflow TimerHigh Frequency Intensity Control Shielding Gas− Maintenance & Troubleshooting Routine Maintenance MonthsAdjusting Spark Gaps Troubleshooting Trouble Remedy− Electrical Diagrams Circuit Diagram For 115 Volts ModelCircuit Diagram For 230 Volts Model Incorrect Installation − High FrequencyWelding Processes Requiring High Frequency Weld ZoneMetal Building Requirements Correct InstallationMetal Building Amperage Range Gas Type Polarity AC − Argon AC − Argon −− Guidelines for TIG Welding Gtaw Preparing Tungsten Electrode For WeldingPositioning The Torch Preparing Tungsten For Conventional AC WeldingTorch Movement During Welding Positioning Torch Tungsten For Various Weld JointsTungsten Without Filler Rod Tungsten With Filler RodReturn To Table Of Contents − Parts List Complete Assembly Part 1 of 2 115V ModelComplete Assembly Part 1 Complete Assembly Part 2 of 2 115V Model Complete Assembly Part 2 Page Page Page Service SupportOwner’s Record Miller Electric Mfg. Co