5-2. Optional Auxiliary Power Receptacles
1
4
5
2
4
5
3
If unit does not have GFCI receptacles, use
.Auxiliary power decreases as weld current increases.
Set Fine Adjust control R1 at 10 for full auxiliary power.
Combined output of all receptacles limited to 8 kVA/kW rating of the generator.
120 Volt Receptacle Option
1120 V 15 A AC Receptacles RC2 And RC3
RC2 and RC3 supply 60 Hz single- phase power at weld/power speed. Maximum output from RC2 or RC3 is 2.4 kVA/kW (CSA: 1.8 kVA/kW). Circuit breaker protection is the same as standard receptacles.
South African And Australian Receptacle Options
2240 V 16 A AC South African Receptacles RC1, RC2, And RC3
3240 V 15 A AC Australian Receptacles RC1, RC2, And RC3
Receptacles supply 60 Hz single- phase power at weld/power speed. Maximum output from each recep- tacle is 3.6 kVA/kW.
4Circuit Breakers CB1, CB2, CB3
CB1, CB2, and CB3 protect RC1, RC2, and RC3 from overload. If a circuit breaker opens, the recep- tacle does not work. Press button to reset breaker.
5 Circuit Breaker CB4
CB4 protects all the receptacles from overload. If CB4 opens, none of the receptacles work.
.If a circuit breaker continues to open, contact a Factory Au- thorized Service Agent.