Miller Electric pmn Torch Dimensions And Weight, Selecting a Location, Location And Airflow

Page 16

4-4. Torch Dimensions And Weight

1 in

8-3/8 in

(213 mm)

(25 mm)

 

 

1-3/8 in

3.0 lb (1.4 kg)

(35 mm)

 

Ref. 802 877

4-5. Selecting A Location

 

 

8-1/2 in

 

(216 mm)

Dimensions And Weight

12-5/16 in*

 

49 lb (22.2 kg)

(313 mm)

not including torch

 

*Add 13/16 in (21 mm) for handle.

16 in

(406 mm)

Movement

1

Lifting Handle

 

1

 

Use handle to lift unit.

2

2

Hand Cart

 

Use cart or similar device to move

 

unit.

 

3

120 VAC Receptacle

 

To connect unit to 230 VAC input

Location And Airflow

power, a customer supplied plug is

necessary (see Section 4-9).

 

 

Locate unit near correct input

 

power supply.

. Serial Number/Rating Label located on

!

Special installation may be

rear panel of plasma cutter; use label to

 

required where gasoline or

determine input power for unit.

 

 

volatile liquids are present −

 

 

3

 

see NEC Article 511 or CEC

 

Section 20.

10 in

(254 mm)

10in

(254 mm)

loc_2 3/96 - Ref. 804 486-A / 804 487-A / 804 488-A

OM-228 305 Page 12

Image 16
Contents Description OM-228 305D 2007−06 ProcessesFile Plasma Cutters Page Table of Contents Page Symbol Usage Plasma Arc Cutting HazardsCutting can cause fire or explosion Electric Shock can killFlying Sparks can cause injury ARC Rays can burn eyes and skinNoise can damage hearing Fumes and Gases can be hazardousHOT Parts can cause severe burns Falling Unit can cause injuryMoving Parts can cause injury Fire or Explosion hazardCalifornia Proposition 65 Warnings Principal Safety Standards EMF InformationAbout Implanted Medical Devices Signification des symboles − Consignes DE Sécurité − Lire Avant UtilisationLE Coupage présente un risque de feu ou d’explosion UN Choc Électrique peut tuerLE Bruit peut endommager l’ouïe Risque de blessure en casLES Fumées ET LES GAZ peuvent être dangereux LE Plasma D’ARC peut entraîner des blessures LES Bouteilles peuvent exploser si elles sont endommagéesDES Pieces Chaudes peuvent pro- voquer des brûlures graves DES Organes Mobiles peuvent provoquer des blessuresProposition californienne 65 Avertissements LA Chute DE L’APPAREIL peut blesserRisque D’INCENDIE OU LE Coupage à L’ARC peut causer des interférenceInformation EMF Principales normes de sécuritéEn ce qui concerne les implants médicaux I1max − DefinitionsI1eff − Installation SpecificationsSpecifications For Torch Duty Cycle And OverheatingTorch Dimensions And Weight Dimensions And WeightSelecting a Location Location And AirflowConnecting Gas/Air Supply Connecting Work Clamp Connecting Input PowerInstalling Alternative Plug Setting Gas/Air Pressure − OperationControls 60 PSITrigger Safety Lock Cutting SpeedSequence Of Operation Sparks go thru metal− Maintenance & Troubleshooting Routine MaintenanceDisconnect power Before maintainingChecking Torch Shield Cup Shutdown System Cup Light Lights if shield cup is looseTorch Connections Torch And Work Cable ConnectionsWork Cable Connections Turn Off power source before checking torch parts Checking/Replacing Retaining Cup, Tip, And ElectrodeTroubleshooting Power Source Yes gas/air flow at torch. CheckTroubleshooting Torch − Electrical Diagram Circuit Diagram− Parts List Main AssemblyDiagram Part Marking Description Quantity Torch, ICE-27C Page Page Warranty Owner’s Record

pmn specifications

Miller Electric, a renowned name in the field of welding and cutting equipment, has consistently delivered advanced solutions that cater to the diverse needs of professionals in various industries. One of their standout products is the Miller Electric PMN (Power Management Network), which exemplifies the company's commitment to innovation and efficiency.

The PMN is designed to optimize the energy consumption of welding machines, allowing users to manage, monitor, and control their equipment with remarkable precision. This system highlights Miller's focus on integrating technology into welding processes to make them more efficient and sustainable.

A key feature of the PMN is its ability to provide real-time data and insights into machine performance. This data can be accessed through a user-friendly interface, enabling users to monitor welding parameters, energy consumption, and productivity levels. The PMN system also enhances equipment reliability by allowing for predictive maintenance. Through continuous monitoring, it can identify potential issues before they escalate, thereby reducing downtime and repair costs.

The PMN employs state-of-the-art communication technologies, including wireless connectivity, which allows operators to manage multiple machines from a centralized location. This is particularly beneficial in larger operations where coordination of multiple units is essential for maintaining workflow efficiency.

Another significant characteristic of the Miller PMN is its adaptability and scalability. Whether you have a small workshop or a large manufacturing facility, the PMN can scale to meet your needs. This modular design ensures that businesses can invest in the capabilities they require now and expand as their operations grow.

Additionally, the PMN incorporates advanced safety features. It can detect irregularities that may pose safety risks, providing alerts to operators. This proactive approach helps ensure a safer working environment, which is a priority for Miller Electric.

In summary, the Miller Electric Power Management Network represents a significant advancement in welding technology, offering features that enhance productivity, efficiency, and safety while reducing operational costs. With its combination of real-time monitoring, wireless capabilities, scalability, and safety features, the PMN is a valuable asset for any welding operation looking to streamline processes and increase overall effectiveness. As industries evolve toward greater energy efficiency and connectivity, Miller Electric continues to lead the way with innovative solutions like the PMN.