INSTALLATION (cont’d)

VENT LINE AND FILTER INSTALLATION

Holding tank vent lines must be free of low points which can trap liquid and prevent the free flow of gases from or air into the holding tanks.

Do not use non-reinforced hose for vent lines. It will tend to kink over time effectively block vent.

A holding tank vent filter will absorb heavier than air gases associ- ated with sewage and eliminate a source of malodor from the exterior of the boat. See vent filter details in this guide.

When installing vent filters that are not mounted directly on an HTS unit:

Avoid areas near excessive heat sources such as engine manifolds or lights.

Do not install the filter below top of holding tank.

The filter can be mounted in any position. Installations near the through-hull vent reduce the chance of filter damage from overfilling of the holding tank.

SERVICE ACCESS

Because SeaLand holding tanks may require minimal service in normal operation, the tank must be installed so that there is easy access to the tank inspection port, discharge pump and vent filter (if installed).

An in-line maintenance valve must be installed in any piping runs which retain liquid and are connected to components that may require periodic servicing (such as discharge pumps).

CLEANING

A small amount of water remains in all marine holding tanks. It is good practice to rinse the tank after the contents have been discharged. This can be accomplished by adding water to the toilet bowl. Add 8 ounces (237ml) of SeaLand® Holding Tank Deodorant and Cleaner to the bowl. Flush the entire contents into the holding tank and continue flushing until the discharge from the holding tank is clear.

Do not use chlorine-based cleaners, caustic cleaners or chemicals, such as drain-opening products, as they may damage the system’s seals and hose.

WINTERIZING

If using the HTS with SeaLand’s VacuFlushcomponents, refer to VacuFlush Owner’s Manual for winterization instruc- tions. If using antifreeze to winterize the HTS, use only propylene glycol freshwater antifreeze that does not contain alcohol. Antifreeze that contains alcohol will result in damage to your sanitation system.

1.Pump out holding tank.

2.Thoroughly flush the system with fresh water before adding propylene glycol freshwater antifreeze to the HTS.

5

Image 5
Contents Dometic Corporation Sanitation Systems Basic Holding Tank SystemFeatures Table of ContentsChoosing a Location for the Basic HTS InstallationPreparing a Mounting Surface Avoiding Hose Odor PermeationPlumbing Connections and Hose Layouts Installation cont’dWinterizing CleaningHose Fittings Plumbing FITTINGS, Hose and PipeOptional HTS Components Ordering Parts Customer ServiceManufacturers ONE-YEAR Warranty

BASIC HOLDING TANK SYSTEM specifications

The SeaLand BASIC HOLDING TANK SYSTEM is a cutting-edge solution designed for the effective management of wastewater in marine environments. This system is particularly beneficial for boats, yachts, and RVs, where space and efficiency are paramount. The innovative design focuses on ease of use, durability, and environmental compliance, making it an ideal choice for both leisure and professional maritime activities.

One of the standout features of the SeaLand BASIC HOLDING TANK SYSTEM is its compact construction. It is engineered to fit seamlessly into tight spaces, which is crucial for vessel designs where every inch counts. The system typically includes a robust tank, valves, and a macerator pump, all constructed from high-quality, corrosion-resistant materials to withstand harsh marine conditions.

Another significant characteristic is the user-friendly interface. The system usually comes equipped with a reliable and easily accessible control panel that allows users to monitor tank levels and manage the pump operation effectively. This ensures that waste is disposed of promptly, reducing the risk of overflow and potential environmental hazards.

The SeaLand BASIC HOLDING TANK SYSTEM also incorporates advanced technologies for odor control and waste management. These systems often feature integrated ventilation and treatment processes that help minimize unpleasant odors, ensuring a comfortable environment onboard. Notably, many models utilize a macerator pump that grinds waste into a slurry, facilitating smooth and clog-free pumping.

Environmental compliance is a core element of the SeaLand BASIC HOLDING TANK SYSTEM. With increasing regulations governing waste disposal in marine environments, this system is designed to meet or exceed industry standards. It ensures responsible waste management, helping boaters maintain compliance while protecting marine ecosystems.

Additionally, SeaLand provides robust customer support and resources to help users install and maintain the holding tank system, ensuring optimal performance throughout its lifespan. The combination of engineering excellence, user convenience, and environmental responsibility makes the SeaLand BASIC HOLDING TANK SYSTEM a leading choice for anyone seeking efficient waste management solutions at sea. In summary, it embodies a perfect blend of functionality, technology, and commitment to sustainability, setting a high standard in the marine industry.