SeaLand BASIC HOLDING TANK SYSTEM owner manual Optional HTS Components

Page 7

OPTIONAL HTS COMPONENTS

TankWatch® 4 Level Monitor and Micro-Float Switches

Includes four tank level indicator lights – Empty, Low, Mid and Full, and international symbology of four tank levels. One light is always on. Reliable micro-float switches are installed in holding tank. No electrical components come in contact with waste or water. Operates on 12 or 24-volt DC. Uses only .017 amps at 13-volts.

Lighted

Tank Level

Monitor

Micro-Float

Switches and

Tank Cap

Toilet System Shut-Off Relay

Shuts down electrically operated toilet systems, including VacuFlush, when holding tank is full. Operates with TankWatch 4 level monitor. Available in 12- or 24-volt DC. (Not shown.)

TankMaster™ 4 Automatic Discharge Pump Control

Increases owner convenience and simplifies plumbing system layout. Diverts sewage directly overboard in unre- stricted waters with the simple turn of optional keyed control switch to “automatic” position. Prevents accidental overboard discharge in restricted waters

when control switch is turned to “off” position. Simpli- fies plumbing by eliminating wye valves, seacocks and vented loops. Automatically maintains holding tank at empty level and eliminates stagnating sewage stand- ing in interconnecting hoses. Works in conjunction with optional discharge pump, TankWatch level indicators and seacock interlock system.

SaniGard™ Holding Tank Vent Filter

The vent filter stops odors that escape from the holding tank vent. It contains odor-removing filter media to keep your boat smelling clean and pleasant. Each cartridge is good for an entire season and is easily replaced for a fresh start. The vent filter includes mounting brackets and hose adapters, and is available with either 5/8" (16mm) (p/n 309310002), 1" (25mm) (p/n 309310005) or 1½" (38mm) (p/n 309310003) hose fittings.

SaniPump™ Overboard Waste Discharge Pump

This T-series discharge pump can run dry without harm and draws just 6 amps at 12 VDC. Delivers flow rate of just over 3.9 gallons per minute (14.7 liters per minute). Emptying the tank of a 10-gallon tank takes about three minutes, and for a 42-gallon tank, about 11 minutes.

The discharge pump is connected to a through-hull fitting. Check Marine Sanitation Regulations for informa- tion on areas where discharge is allowed. 12 VDC model – p/n 360301200. 24 VDC model – 360302400.

7

Image 7
Contents Dometic Corporation Sanitation Systems Basic Holding Tank SystemFeatures Table of ContentsAvoiding Hose Odor Permeation InstallationChoosing a Location for the Basic HTS Preparing a Mounting SurfacePlumbing Connections and Hose Layouts Installation cont’dWinterizing CleaningHose Fittings Plumbing FITTINGS, Hose and PipeOptional HTS Components Manufacturers ONE-YEAR Warranty Customer ServiceOrdering Parts

BASIC HOLDING TANK SYSTEM specifications

The SeaLand BASIC HOLDING TANK SYSTEM is a cutting-edge solution designed for the effective management of wastewater in marine environments. This system is particularly beneficial for boats, yachts, and RVs, where space and efficiency are paramount. The innovative design focuses on ease of use, durability, and environmental compliance, making it an ideal choice for both leisure and professional maritime activities.

One of the standout features of the SeaLand BASIC HOLDING TANK SYSTEM is its compact construction. It is engineered to fit seamlessly into tight spaces, which is crucial for vessel designs where every inch counts. The system typically includes a robust tank, valves, and a macerator pump, all constructed from high-quality, corrosion-resistant materials to withstand harsh marine conditions.

Another significant characteristic is the user-friendly interface. The system usually comes equipped with a reliable and easily accessible control panel that allows users to monitor tank levels and manage the pump operation effectively. This ensures that waste is disposed of promptly, reducing the risk of overflow and potential environmental hazards.

The SeaLand BASIC HOLDING TANK SYSTEM also incorporates advanced technologies for odor control and waste management. These systems often feature integrated ventilation and treatment processes that help minimize unpleasant odors, ensuring a comfortable environment onboard. Notably, many models utilize a macerator pump that grinds waste into a slurry, facilitating smooth and clog-free pumping.

Environmental compliance is a core element of the SeaLand BASIC HOLDING TANK SYSTEM. With increasing regulations governing waste disposal in marine environments, this system is designed to meet or exceed industry standards. It ensures responsible waste management, helping boaters maintain compliance while protecting marine ecosystems.

Additionally, SeaLand provides robust customer support and resources to help users install and maintain the holding tank system, ensuring optimal performance throughout its lifespan. The combination of engineering excellence, user convenience, and environmental responsibility makes the SeaLand BASIC HOLDING TANK SYSTEM a leading choice for anyone seeking efficient waste management solutions at sea. In summary, it embodies a perfect blend of functionality, technology, and commitment to sustainability, setting a high standard in the marine industry.