Chauvet 60825-1:2007 manual Setup, AC Power, Fuse Replacement, Mounting

Page 10

3.SETUP

AC Power

This fixture has an auto-switching power supply that can accommodate a wide range of input voltages. The only thing necessary to do before powering on the unit is to make sure the line voltage you are applying is within the range of accepted voltages. This fixture will accommodate 100~240 VAC, 50/60 Hz.

Always connect the product to a switched circuit. Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used only as a 0 to 100% switch.

Fuse Replacement

With a flat head screwdriver, wedge the fuse holder out of its housing. Remove the damaged fuse from its holder and replace with exact same type fuse.

Insert the fuse holder back in its place and reconnect power.

The fuse is located inside this compartment. Remove using a flat head screwdriver.

Disconnect the power cord before replacing a fuse and always replace with the same type fuse.

Mounting

Orientation

This fixture may be mounted in any safe position, provided there is adequate room for ventilation.

Rigging

It is important never to obstruct the fan or vents pathway. Mount the fixture using, a suitable C or O type clamp. Adjust the angle of the

fixture by loosening both knobs and tilting the fixture. After finding the desired position, retighten both knobs.

Hanging Clamp

When selecting installation location, take into consideration access and routine maintenance.

Safety cables must always be used.

Never mount in places where the fixture will be exposed to rain, high humidity, extreme temperature changes or restricted ventilation.

Note!

Clamp is sold separately.

Scorpion™ Storm FXGB User Manual

10

12/12/2011

Image 10
Contents Page Table of Contents Contact InformationBefore YOU Begin Safety Instructions Laser Safety Notes Non Interlocked Housing WarningLaser Safety Label Reproduction Laser Emission Data Laser Compliance StatementIntroduction Product OverviewProduct Dimensions Fuse Replacement SetupAC Power MountingProper Usage Data Cabling Cable ConnectorsFixture Linking DMX Data CableSetting up a DMX Serial Data Link Pin to 5-Pin Conversion ChartMaster/Slave Fixture Linking DMX Channel Summary Operating InstructionsNavigating the Control Panel Menu FunctionsControl Mode DMX Channel ValuesSetting the Starting Address General Troubleshooting Technical SupportAppendix DMX PrimerReturns Procedure Technical Specifications Power