Agilent Technologies 85054-90049 manual Replaceable Parts for the 85054B Calibration Kit, Adapters

Page 50

Replaceable Parts

Introduction

Introduction

Table 6-1lists the replacement part numbers for items included in the 85054B calibration kit and Figure 6-1illustrates each of these items.

Table 6-2lists the replacement part numbers for items recommended or required for successful operation but not included in the calibration kit.

To order a listed part, note the description, the part number, and the quantity desired. Refer to “Contacting Agilent” on page 5-3.

Table 6-1 Replaceable Parts for the 85054B Calibration Kit

Item No.

Description

 

Qty Per

Agilent Part Number

 

 

 

Kit

 

 

 

 

 

 

 

Calibration Devices (50Ω Type-N)

 

 

 

 

 

 

 

1

Type-N (m) sliding load

 

1

85054-60035

 

 

 

 

 

2

Type-N (f) sliding load

 

1

85054-60036

 

 

 

 

 

3

Type-N (m) lowband load

 

1

00909-60011

 

 

 

 

 

4

Type-N (f) lowband load

 

1

00909-60012

 

 

 

 

 

5

Type-N (m) offset short

 

1

85054-60025

 

 

 

 

 

6

Type-N (f) offset short

 

1

85054-60026

 

 

 

 

 

7

Type-N (m) offset open

 

1

85054-60027

 

 

 

 

 

8

Type-N (f) offset open

 

1

85054-60028

 

 

 

 

 

 

Adapters

 

 

 

 

 

 

 

9

Type-N (m) to Type-N (m)

 

1

85054-60038

 

 

 

 

 

10

Type-N (f) to Type-N (f)

 

1

85054-60037

 

 

 

 

 

11

Type-N (f) to 7 mm

 

2

85054-60031

 

 

 

 

 

12

Type-N (m) to 7 mm

 

2

85054-60032

 

 

 

 

 

 

Wrenches

 

 

 

 

 

 

 

13

3/4 in., 135 N-cm (12 in-lb) Torque

 

1

8710-1766

 

 

 

 

 

14

Spanner

 

1

08513-20014

 

 

 

 

 

 

Calibration Kit Storage Case

 

 

 

 

 

 

 

15

Storage Case Assembly (includes items listed below)

 

1

85054-60039

 

 

 

 

 

16

Box

 

1

5180-7900

 

 

 

 

 

17

ID label

 

1

85054-80012

 

 

 

 

 

18

Foam pad (bottom)

 

1

85054-80023

 

 

 

 

 

19

Foam pad (lid)

 

1

5181-5543

 

 

 

 

 

6- 2

85054B

Image 50
Contents User’s and Service Guide Manufacturing Part Number Print Date JuneDocumentation Warranty Contents Replaceable Parts General Information Kit Contents Calibration Kit OverviewCalibration Definitions Equipment Required but Not SuppliedIncoming Inspection Serial Number Record for the 85054B Serial NumbersRecording the Device Serial Numbers 85054B Kits with Serial Prefix 2906A Calibration Kits Documented in This ManualCalibration Kit History Precision Slotless Connectors Clarifying the Sex of a Connector Preventive MaintenanceSpecifications Environmental Requirements Temperature-What to Watch Out ForEnvironmental Requirements Mechanical Characteristics Pin DepthPin Depth Limits Certification Electrical SpecificationsElectrical Specifications Electrical Specifications 85054B Use, Maintenance, and Care of the Devices ESD Protection Setup Electrostatic DischargeLook for Obvious Defects and Damage First What Causes Connector Wear?Visual Inspection Inspect the Mating Plane SurfacesUse Compressed Air or Nitrogen Cleaning ConnectorsInspect the Precision Slotless Connectors female Clean the Mating Plane Surfaces InspectGaging Connectors Connector Gage AccuracyWhen to Gage Connectors Reading the Connector GageGaging Procedures Gaging Male Type-N ConnectorsGaging Male Type-N Connectors Gaging Female Type-N Connectors Gaging Female Type-N Connectors Gaging the Sliding Load Adjusting the Sliding Load Pin Depth Gaging the Sliding Load Pin DepthGaging Connectors Adjusting the Sliding Load Pin Depth Connections How to Make a ConnectionFinal Connection Using a Torque Wrench Preliminary ConnectionWrench Positions Connecting the Sliding Load How to Separate a Connection Connecting the Sliding LoadUsing the Sliding Load 10 Using the Sliding Load Handling and Storage Performance Verification Introduction How Agilent Verifies the Devices in This KitHow Often to Recertify Where to Send a Kit for RecertificationRecertification Recertification 85054B Troubleshooting Troubleshooting Process Troubleshooting FlowchartContacting Agilent Where to Look for More InformationReturning a Kit or Device to Agilent Contacting AgilentReturning a Kit or Device to Agilent 85054B Replaceable Parts Replaceable Parts for the 85054B Calibration Kit AdaptersItem No Description Replaceable Parts-Items Not Included in the Calibration Kit ESD Protective DevicesReplaceable Parts for the 85054B Calibration Kit More Replaceable Parts for the 85054B Calibration Kit Standard Definitions Version Changes Standard Class Assignments Class Standard Class LabelCalibration Kit Label N 50 Ω If you are performing an LRM calibration If you are performing a TRL calibrationIf you are performing a TRM calibration Standard Class Assignments Blank Forms Table A-4 Blank Form for the 8510 Network AnalyzerS11A S11B S11C S22A S22B S22C Table A-6 Blank Form for the PNA Series Network Analyzers Standard Class Assignments Setting the System Impedance Nominal Standard DefinitionsTable A-7 Standard Definitions for the 8510 Network Analyzer Calibration Kit Label N 50 Ω Frequency Standardb Offset GHzc Table A-10 Blank Form for the 8510 Network Analyzer Coax or Waveguide Standard LabelSystem Z 0 a = 50.0 Ω Frequency Standard b Offset GHz c Nominal Standard Definitions 85054B Index Index-2 85054B Index-3

85054-90049 specifications

Agilent Technologies 85054-90049 is a high-performance calibration kit designed for vector network analysis across a wide range of frequencies. This kit is an indispensable tool for engineers and technicians involved in the measurement and characterization of RF components, ensuring accuracy and reliability in their testing processes.

One of the main features of the 85054-90049 calibration kit is its ability to provide accurate calibration across multiple frequency bands, including microwave and millimeter-wave frequencies. This versatility is crucial for professionals who work with different types of RF devices, such as amplifiers, filters, and antennas. The kit supports a frequency range of up to 67 GHz, making it suitable for a variety of applications in the telecommunications and aerospace industries.

The calibration kit utilizes precision standards and adapters that ensure low insertion loss and minimal reflection. These components are engineered to provide high stability and repeatability in measurements, which is vital for maintaining quality control in manufacturing processes or during research and development stages. The accuracy of the calibration is further enhanced by the materials used in the construction of the connectors and adapters, which are designed to minimize signal degradation.

Another key technology employed in the Agilent 85054-90049 is its rugged design, intended to withstand the demands of laboratory environments as well as field applications. The kit is portable, allowing engineers to perform precision measurements wherever needed without compromising on performance. Its compact design and durable case make it an ideal choice for field applications.

The 85054-90049 calibration kit is also compatible with Agilent's range of vector network analyzers, creating a seamless user experience. The calibration process, supported by comprehensive software tools, is designed to be user-friendly, allowing technicians to perform calibrations quickly and accurately. In addition, the kit comes with detailed documentation that includes calibration procedures, ensuring that even those new to RF testing can follow along with ease.

In summary, the Agilent Technologies 85054-90049 is a state-of-the-art calibration kit that combines high performance, compatibility, and durability. Its advanced features cater to various RF testing needs, making it a vital resource for professionals in industries where precision measurements are of utmost importance. Whether in laboratories or field settings, this calibration kit stands out as a benchmark for quality in RF and microwave measurement applications.