OPERATING PROCEDURES
Start-up (Fig. 1, pg. 2)
•Connect the tool to air source with the hose of recommended size.
•Turn on the air compressor and allow the air tank to be filled.
•Set the air compressor regulator to 90 PSI. This air tool operates at a maximum of 90 PSI air pressure.
•Push the safety lever forward (1) while depressing the trigger (2) to start operating the tool.
2
1
Shut-down (Fig. 1, pg. 2)
•Release the trigger in order to stop the tool.
•Fix/take away the insert tool.
•When job is completed, turn off the air compressor and store the air tool after lubrication. For safety, put the tool on a hanger or on a soft flat pad when not in use.
•When changing grinding attachments and accessories, always disconnect the air supply to avoid injury.
OPERATING INSTRUCTIONS
•To begin operation, grip tool and depress safety throttle lever while engaging the trigger.
•To mount stones and other accessories, use the wrenches supplied with the tool. Always disconnect air supply before changing any accessories.
•The grinder should be gradually applied to the work surface until the stone or burr becomes worn. Always replace excessively worn stones or burrs.
•Make smooth contact with the work and avoid any bumping action or excessive force.
14