Sanyo TS3632, TS2432, TS4232, XS2432 Remote Control Unit, Cool, Fan, Hour OFF Timer, ALL Clear

Page 10

Remote Control Unit (continued)

PROGRAM button

For details, see ``Setting the Timer''.

 

 

 

Press this button to select the mode you want to program.

 

 

 

 

TIMER SELECT button

No display : The timer does not operate.

 

 

 

OFF

: The air conditioner stops at the set time.

 

 

 

ON

: The air conditioner starts at the set time.

 

 

 

 

: The air conditioner stops and starts, or starts and stops, at

 

 

 

 

the set times every day.

 

 

 

 

MODE selector button

Use this button to select COOL or FAN mode

 

(COOL)

 

: The air conditioner makes the room cooler.

 

(FAN)

 

: The air conditioner works only as a circulation fan.

 

 

 

 

FLAP button

Press this button to select the sweep function, which moves the flap up

 

 

 

and down automatically.

 

 

 

 

: The flap moves up and down automatically.

 

 

 

 

 

FAN SPEED selector

 

: The air conditioner automatically decides the fan speeds.

 

button

 

: High fan speed

 

 

 

 

: Medium fan speed

 

 

 

 

: Low fan speed

 

 

 

 

 

1 HR. TIMER button

1

: When you press this button, regardless of whether the unit is

(1-HOUR OFF TIMER)

 

operating or stopping, the unit operates for one hour and then

 

 

 

 

shuts down.

 

 

 

 

ACL button

Puts the remote control unit into pre-operation status. Always press this

(ALL CLEAR)

button after replacing the batteries.

 

 

 

 

A/C SENSOR button

When you press this button (use a small-tipped object such as a

 

 

 

ballpoint pen), the mark will appear at the display. And the room

 

 

 

temperature is detected by the sensor which is built into the indoor unit

 

 

 

and the air conditioner is controlled accordingly.

 

 

 

If the remote control is located near a heat source, such as a space

 

NOTE

 

 

 

heater or in direct sunlight, press the A/C SENSOR button to switch to

 

 

 

 

 

 

the sensor on the indoor unit.

 

 

 

 

 

NOTE

·

·

The remote control unit sends the temperature signal to the air conditioner regularly at three minute intervals. If the signal from the remote control unit stops for more than ten minutes due to the loss of the remote control unit or other trouble, the air conditioner will switch to the temperature sensor which is built into the indoor unit and control the room temperature. In these cases, the temperature around the remote control unit may differ from the temperature detected at the air conditioner's position.

Operation when the outdoor temperature is low

If an indoor unit connected to a ``CL-'' type outdoor unit is operating in the cooling mode during the winter months when the outdoor temperature is low, setting the FAN SPEED selector to (low fan speed) can result in intermittent operation to prevent freezing. In such cases, use the (high fan speed) or (medium fan speed) setting instead.

10

OI-201-10EG

Image 10
Contents Split System Air Conditioner · Microprocessor Controlled Operation · Air Sweep Control FeaturesHour OFF Timer Night SetbackAlert Symbols ContentsProduct Information Electrical Requirements Installation LocationSafety Instructions CL ModelNames of Parts Outdoor condensing unitRecessed type Ceiling mounted type Control Operation TimerRemote Indoor Unit Unit Display and Operation SelectorDo not set at the Test position for normal operation 1HR Cover closed Sensor TransmitterDisplay SensorCool Remote Control UnitHour OFF Timer FANHow to Use the Remote Control Unit Using the Remote Control UnitHow to Install Batteries Remote Control Unit Installation PositionUsing the Remote Control Unit Mounting the Remote Control UnitOperation Operation with the Remote Control UnitStep Fan Only Operation with the Remote Control UnitAdjusting the Fan Speed FAN SpeedSetting Temperature Min Press Night Setback ModeNight Setback Mode is used for saving energy Night SetbackPower failure during operation Remote Control Unit Special RemarksHow to set the present time How to set the OFF time Setting the TimerOperation Indication Setting the Timer Operation Together with the Program Timer Using the 1-Hour OFF TimerHour OFF Timer Setting procedureOperation without the Remote Control Unit Adjusting the Airflow DirectionCooling Care and Cleaning Latch Safety string Air intake grille Bolt screw Air filterHow to remove the filter Ceiling mounted type Care and CleaningAir filter Pull down How to clean the filter Outdoor Unit Tips for Energy Saving TroubleshootingShould the power fail while the unit is running Operating RangeSanyo Canada Inc CanadaSanyo Fisher Company Division of Sanyo North America Corporation
Related manuals
Manual 24 pages 34.26 Kb Manual 50 pages 44.29 Kb

KS2432, KS3632, KS3032, XS3632, XS4232 specifications

The Sanyo XS2432, KS2432, TS2432, TS3632, and XS4232 are notable products in the Sanyo line, designed for a variety of users seeking high-quality performance in their electronic devices. These models reflect Sanyo's commitment to innovation, efficiency, and user-friendly features that appeal to both residential and commercial settings.

The Sanyo XS2432 and KS2432 are versatile models typically used in home environments for air conditioning solutions. With advanced inverter technology, these units not only ensure a consistent indoor climate but also optimize energy consumption. The whisper-quiet operation is enhanced by sophisticated noise-reducing features, making them ideal for bedrooms and living spaces. Additionally, the built-in air purification mechanism significantly improves indoor air quality, filtering out dust, allergens, and other pollutants.

In contrast, the TS2432 and TS3632 models are designed for heavier-duty applications, often found in commercial settings. These units offer robust cooling and heating capabilities with extended operational ranges to suit different environmental conditions. Equipped with smart thermostat technology, they can automatically adjust their output based on room occupancy and temperature, resulting in enhanced efficiency and comfort. The rugged build quality of the TS series ensures longevity and reliability, even in demanding conditions.

The XS4232 rounds out the lineup by combining features from both the XS and TS series. It boasts advanced control systems that enable users to monitor and manage energy use through smartphone apps, allowing for remote operation. The XS4232 provides multi-zone cooling and heating options, making it suitable for larger spaces or buildings where different areas may require different climatic conditions.

Across all these models, the hallmark of Sanyo's design philosophy is energy efficiency. Many of the units carry high SEER (Seasonal Energy Efficiency Ratio) ratings, translating to lower electricity bills and reduced environmental impact. Moreover, the easy-to-use interfaces and straightforward installation processes are designed with the user in mind, enhancing the overall experience.

In summary, the Sanyo XS2432, KS2432, TS2432, TS3632, and XS4232 serve a broad range of needs from residential climate control to commercial application. With features such as smart technology, advanced filtration, and energy-efficient designs, Sanyo continues to lead the way in providing reliable and effective temperature management solutions for diverse environments.