Sanyo XS1822 Installation Location, Electrical Requirements, Safety Instructions, CL Model

Page 4

Installation Location

·We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit.

·Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate.

· Do not install this air conditioner where there are fumes or flammable gases, or in an extremely humid space such as a greenhouse.

·Do not install the air conditioner where excessively high heat- generating objects are placed.

Avoid:

·

To protect the air conditioner from heavy corrosion, avoid installing the

 

 

outdoor unit where salty sea water can splash directly onto it or in

 

 

sulphurous air near a spa.

 

·

The unit may malfunction when the receiver in the indoor unit is

 

 

exposed to the inverter lamp light.

CAUTION

Electrical Requirements

1.All wiring must conform to the local electrical codes. Consult your dealer or a qualified electrician for details.

2.Each unit must be properly grounded with a ground (or earth) wire or through the supply wiring.

3.Wiring must be done by a qualified electrician.

·Power supply: 60 Hz, single-phase, 230/208 volts.

To warm up the system, the power mains

Power mains

 

must be turned on at least five (5) hours

ON

before operation. Leave the power mains

ON unless you will not be using this

 

appliance for an extended period.

 

(CL MODEL)

 

 

 

CAUTION

4

Safety Instructions

·Read this Instruction Manual carefully before using this air conditioner. If you still have any difficulties or problems, consult your dealer for help.

·This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in this Instruction Manual.

·Never touch the unit with wet hands.

·Never use or store gasoline or other flammable vapor or liquid near the air conditioner Ð it is very dangerous.

·This air conditioner has no ventilator for intaking fresh air from outdoors. You must open doors or windows frequently when you use gas or oil heating appliances in the same room, which consume a lot of oxygen from the air. Otherwise there is a risk of suffocation in an extreme case.

·Do not turn the air conditioner on and off from the power mains switch. Use the ON/OFF operation button.

·Do not stick anything into the air outlet of the outdoor unit. This is dangerous because the fan is rotating at high speed.

·Do not let children play with the air conditioner.

·Do not cool the room too much if babies or invalids are present.

OI-201-04EG

Image 4
Contents Split System Air Conditioner Features Hour OFF Timer· Microprocessor Controlled Operation · Air Sweep Control Night SetbackAlert Symbols ContentsProduct Information Installation Location Safety InstructionsElectrical Requirements CL ModelNames of Parts Outdoor condensing unitRecessed type Ceiling mounted type Control Operation TimerRemote Indoor Unit Unit Display and Operation SelectorDo not set at the Test position for normal operation 1HR Sensor Transmitter DisplayCover closed SensorRemote Control Unit Hour OFF TimerCool FANUsing the Remote Control Unit How to Install BatteriesHow to Use the Remote Control Unit Remote Control Unit Installation PositionUsing the Remote Control Unit Mounting the Remote Control UnitOperation Operation with the Remote Control UnitStep Operation with the Remote Control Unit Adjusting the Fan SpeedFan Only FAN SpeedNight Setback Mode Night Setback Mode is used for saving energySetting Temperature Min Press Night SetbackPower failure during operation Remote Control Unit Special RemarksHow to set the present time How to set the OFF time Setting the TimerOperation Indication Setting the Timer Using the 1-Hour OFF Timer Hour OFF TimerOperation Together with the Program Timer Setting procedureOperation without the Remote Control Unit Adjusting the Airflow DirectionCooling Care and Cleaning Latch Safety string Air intake grille Bolt screw Air filterHow to remove the filter Ceiling mounted type Care and CleaningAir filter Pull down How to clean the filter Outdoor Unit Troubleshooting Should the power fail while the unit is runningTips for Energy Saving Operating RangeCanada Sanyo Fisher CompanySanyo Canada Inc Division of Sanyo North America Corporation
Related manuals
Manual 24 pages 34.26 Kb Manual 50 pages 44.29 Kb

KS2432, KS3632, KS3032, XS3632, XS4232 specifications

The Sanyo XS2432, KS2432, TS2432, TS3632, and XS4232 are notable products in the Sanyo line, designed for a variety of users seeking high-quality performance in their electronic devices. These models reflect Sanyo's commitment to innovation, efficiency, and user-friendly features that appeal to both residential and commercial settings.

The Sanyo XS2432 and KS2432 are versatile models typically used in home environments for air conditioning solutions. With advanced inverter technology, these units not only ensure a consistent indoor climate but also optimize energy consumption. The whisper-quiet operation is enhanced by sophisticated noise-reducing features, making them ideal for bedrooms and living spaces. Additionally, the built-in air purification mechanism significantly improves indoor air quality, filtering out dust, allergens, and other pollutants.

In contrast, the TS2432 and TS3632 models are designed for heavier-duty applications, often found in commercial settings. These units offer robust cooling and heating capabilities with extended operational ranges to suit different environmental conditions. Equipped with smart thermostat technology, they can automatically adjust their output based on room occupancy and temperature, resulting in enhanced efficiency and comfort. The rugged build quality of the TS series ensures longevity and reliability, even in demanding conditions.

The XS4232 rounds out the lineup by combining features from both the XS and TS series. It boasts advanced control systems that enable users to monitor and manage energy use through smartphone apps, allowing for remote operation. The XS4232 provides multi-zone cooling and heating options, making it suitable for larger spaces or buildings where different areas may require different climatic conditions.

Across all these models, the hallmark of Sanyo's design philosophy is energy efficiency. Many of the units carry high SEER (Seasonal Energy Efficiency Ratio) ratings, translating to lower electricity bills and reduced environmental impact. Moreover, the easy-to-use interfaces and straightforward installation processes are designed with the user in mind, enhancing the overall experience.

In summary, the Sanyo XS2432, KS2432, TS2432, TS3632, and XS4232 serve a broad range of needs from residential climate control to commercial application. With features such as smart technology, advanced filtration, and energy-efficient designs, Sanyo continues to lead the way in providing reliable and effective temperature management solutions for diverse environments.