CIRCUIT REQUIREMENTS
110V Operation
Amperage Draw
The Model T10010 motor draws the follow- ing amps under maximum load:
Motor Draw | 3 Amps |
Minimum Circuit Requirement
We recommend connecting your machine to a dedicated and grounded circuit that is rated for the amperage given below. Never replace a circuit breaker on an exist- ing circuit with one of higher amperage without consulting a qualified electrician to ensure compliance with wiring codes. If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared circuit, consult a qualified electrician.
110V Circuit | 15 Amps |
Plug/Receptacle Type |
|
Included Plug Type | NEMA |
|
|
|
|
Figure 1. Plug & receptacle type.
Electrocution or fire could result if this
machine is not ground- ed correctly or if your electrical configuration does not comply with local and state codes.
Ensure compliance by checking with a quali- fied electrician!
This machine must have a ground prong in the plug to help ensure that it is grounded. DO NOT remove ground prong from plug to fit into a two- pronged outlet! If the plug will not fit the outlet, have the proper outlet installed by a qualified electrician.
Extension Cords
We do not recommend the use of exten- sion cords, but if you find it absolutely necessary:
•Use at least a 14 gauge cord that does not exceed 50 feet in length!
•The extension cord must also contain a ground wire and plug pin.
•A qualified electrician MUST size cords over 50 feet long to prevent motor dam- age.