Test Run

Once assembly is complete and a grinding wheel is installed (see Installing/Changing

Grinding Wheel on Page 16 for detailed

instructions), test run the grinder to make sure it runs properly and is ready for regular operation.

The test run consists of verifying the following:

The motor powers up and runs correctly.

The safety mechanism works correctly.

Note: The Model T10493 has a locking slide switch. Models T10494 and T10495 have a trigger safety button that must be

depressed before the trigger operates.

If, during the test run, you cannot easily locate the source of an unusual noise or vibration, stop using the tool immediately,

then review Troubleshooting on Page 14.

If you still cannot remedy a problem, con- tact our Tech Support at (570) 546-9663 for assistance.

To test run the grinder:

1.DISCONNECT TOOL FROM POWER!

2.Rotate the wheel by hand and make sure it turns freely and is tightly secure on the spindle.

3.Confirm that the guard and handle are in a safe configuration and securely in place.

T10493, T10494 & T10495 (Mfg Since 10/11)

4.Make sure you have read and understand the safety instructions at the beginning of the manual and that the grinder is setup properly.

5.Connect the grinder to power, as shown on Page 8. For Model T10493 proceed to Step 6; for Models T10494 and T10495 skip to Step 7.

6.While firmly holding the grinder, turn the grinder ON. The switch should lock in the ON position.

If operating correctly, the grinder will remain running. Depressing the switch will make it spring back and turn the tool OFF. The grinder is ready to use.

If the locking slide switch does not automatically return to the OFF position when pressed, it is not functioning properly. Turn the tool OFF and contact Tech Support.

7.Press the safety button then pull the trigger.

If operating correctly, the tool will turn on and remain running as long as you hold down the trigger. Proceed to Step 8.

If the tool does not turn ON the trigger is not working properly. Disconnect power and contact Tech Support.

8.Try to depress the trigger without pressing the trigger safety button.

—If operating correctly, the tool should not turn on. The grinder is ready to use.

If the grinder does turn ON the trigger safety is not working properly. Turn the tool OFF and contact Tech Support.

-9-

Image 11
Contents Models T10493, T10494, T10495 4, 5 & 6 Angle Grinders Page Mation about proper operation of the equipment SafetySafety Instructions For Power Tools Before Operating This EquipmentSafety Instructions for Power Tools Additional Safety Instructions For Angle Grinders Foreword Contact Info IntroductionT10493 T10494 T10495 SpecificationsIdentification Description Qty SetupUnpackingInventory To adjust the guard AssemblyAdjusting the Wheel Guard Installing the HandlePolarized Plug Requirements Power ConnectionConnecting Power Disconnecting PowerTest run consists of verifying the following Then review Troubleshooting onTest Run Grinding Wheel on Page 16 for detailedTo use the angle grinder Using the Angle GrinderOperations Never exceed RPM rating for wheelsG7870 G7872 G7871 G7866 T21767G7867 AccessoriesH4978 T20446 H4979 T20928-Nuisance Dust MaskT24310-6 x 1⁄4, 7⁄8 Bore Grind Wheel T24311-5 x 1⁄4 7⁄8 Bore Grind WheelThese procedures should be done before and after each use MaintenanceRegular Maintenance Symptom Possible Cause Solution ServiceTroubleshooting Step Changing Motor BrushesTools Needed Qty To inspect/change Carbon BrushesTo install or change the wheel Installing/Changing Grinding WheelsT10494 & T10495 Main Breakdown PartsT10494 & T10495 Labels Breakdown T10494 & T10495 Main Parts List3135 T10493 Main BreakdownT10493 Labels Breakdown T10493 Main Parts ListWarranty Order Hours a DAY