EYE INJURY
HAZARD!
Wear protective equipment when using this tool.
Using Grinder
Always test the grinder on a scrap piece of material similar to the workpiece. Trial and error is the best way to determine the ideal setup.
To use the grinder:
1.Make sure the workpiece is securely held in a vise or a similar device that will ensure the workpiece does not unexpectedly move during operation.
2.Attach the grinder to an air supply set at 90 PSI.
3.Hold the grinder securely, turn the grinder ON by depressing the trigger, then ease the grinding wheel against the workpiece with a light, but steady, pressure.
Note: Vary the grinding wheel speed by the pressure used on the trigger.
4.To turn the grinder OFF, release the trigger.
Note: To avoid accidental start up, dis- connect the grinder from the air supply when it is not in use, and replace the protective cap into the air inlet port.
LUNG/EAR INJURY
HAZARD!
Wear protective equipment when using this tool.
ACCIDENTAL START
HAZARD!
Disconnect before
service or tool
changes.
AIR PRESSURE
HAZARD!
Never exceed max
PSI rating for tool.
Daily Maintenance
The angle grinder MUST have
These procedures should be done after each use:
•Wipe the grinding housing with a dry cloth, or blow off the dust and debris with compressed air.
•Check for damage to grinding wheels, hoses, housing, or other accessories.
Quick | Quick | Lubricator | |
Connector | Connector | Regulator | |
Your |
|
| Air |
Tool |
|
| Compressor |
Quick |
|
|
|
Coupler |
| Quick |
|
| Air Hose | Filter | |
| Coupler | ||
|
|
Figure 3. Installed filter lubricator
regulator.
T23083 (Mfg Since 11/10) |