Harbor Freight Tools 68341 Symbology, Table a Recommended Minimum Wire Gauge for Extension Cords

Page 6

4.When using more than one extension cord to make up the total length, make sure each cord contains at least the minimum wire size required. (See Table A.)

5.If you are using one extension cord for more than one tool, add the nameplate amperes and use the sum to determine the required minimum cord size. (See Table A.)

6.If you are using an extension cord outdoors, make sure it is marked with the suffix “W-A” (“W” in

Canada) to indicate it is acceptable for outdoor use.

7.Make sure the extension cord is properly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified electrician before using it.

8.Protect the extension cords from sharp objects, excessive heat, and damp or wet areas.

Table A: RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*

(120/240 VOLT)

NAMEPLATE

 

EXTENSION CORD

AMPERES

 

 

LENGTH

 

(at full load)

25´

 

50´

75´

100´

150´

0 – 2.0

18

 

18

18

18

16

2.1

– 3.4

18

 

18

18

16

14

3.5

– 5.0

18

 

18

16

14

12

5.1

– 7.0

18

 

16

14

12

12

7.1 – 12.0

18

 

14

12

10

-

12.1

– 16.0

14

 

12

10

-

-

16.1

– 20.0

12

 

10

-

-

-

*Based on limiting the line voltage drop to five volts at

150% of the rated amperes.

Symbology

Double Insulated

 

Canadian Standards Association

 

 

 

Underwriters Laboratories, Inc.

 

 

V~

Volts Alternating Current

A

Amperes

 

 

n0 xxxx/min. No Load Revolutions per Minute (RPM)

 

WARNING marking concerning Risk

 

of Eye Injury. Wear ANSI‑approved

 

safety goggles with side shields.

Read the manual before set-up and/or use.

WARNING marking concerning Risk of Hearing Loss.

Wear hearing protection.

WARNING marking concerning Risk of Fire.

Do not cover ventilation ducts. Keep flammable objects away. WARNING marking concerning Risk of Electric Shock.

Properly connect power cord to appropriate outlet.

Page 6

For technical questions, please call 1-800-444-3353.

SKU 68341

Image 6
Contents HP Fixed Base Router RouterImportant Safety Information General Power Tool Safety WarningsSpecifications Save This ManualService Router Safety WarningsPower tool use and care Use personal protective equipmentVibration Safety For technical questions, please call SKUExtension Cords Double Insulated Tools Tools with Two Prong PlugsGrounded Tools Tools with Three Prong Plugs Grounding25´ 50´ 75´ 100´ 150´ SymbologyTable a Recommended Minimum Wire Gauge for Extension Cords 120/240 VoltComponents Instructions for Putting into UseTool Set Up Installing Bits Operating InstructionsAdjusting the Cutting Depth Attaching GuideWork Piece and Work Area Set Up General Operating InstructionsTroubleshooting Cleaning, Maintenance LubricationMaintenance and Servicing Problem Possible Causes Likely SolutionsParts List Part Description QtyRecord Product’s Serial Number Here Assembly Diagram Limited 90 Day Warranty Mission Oaks Blvd. PO Box 6009 Camarillo, CA 93011 800