Operating Instructions

Read the entire Important Safety Information section at the beginning of this manual including all text under subheadings therein before set up or use of this product.

Tool Set Up

To prevent serious injury

from accidental operation:

Turn the Power Switch of the tool off and unplug the tool from its electrical outlet before preparing for

place. Keep the Spindle Lock Button depressed through step 6.

4.Use the Spanner Wrench (51) to loosen the Collet Nut (50).

5.Insert the bit all the way into the Collet. CAUTION! Bits are sharp,

Handle with care.

6.Securely tighten Collet Nut.

7.Release the Spindle Lock Button.

8.Pull up the Lock Lever to free the shaft.

9.Replace the Chip Shield.

Cutting Depth Adjustment

operation.

Installing Bits

Spindle Lock Button (46) Spindle

Chip

Shield

Depth

Stop

Bar (30)

Depth

Adjusting

Bolt (29)

Depth

Stop

Turret

Depth of Cut

(70)

Collet Nut (50)

Figure 2

1.Unthread the Screw (85) holding the Chip Shield (70) in place and remove the Chip Shield.

2.Lock the Plunge Lock Lever (32) in place to keep the shaft stationary.

3.Depress the Spindle Lock Button (46) and rotate the Spindle until it locks in

(67)Screw

(85)

Figure 3

The depth of cut is equal to the dis- tance between the lower end of the Depth Adjusting Bolt (29) and the section of the Depth Stop Turret (67) directly below the Depth Stop Bar (30). First, install the bit you will use for the cut, then adjust the Router as follows to set up the desired cutting depth.

SKU 67119

For technical questions, please call 1-800-444-3353.

Page 12

Image 12
Contents For technical questions or replacement parts, please call Distributed exclusively by Harbor Freight ToolsContents General Power Tool Safety Save This ManualGfci reduces the risk of electric shock Plunge Router Safety Warnings For technical questions, please call Vibration Safety Grounding Grounded Tools Tools with Three Prong PlugsProng Plug and Outlet Plug and OutletDouble Insulated Tools Tools With Two Prong Plugs Extension CordsOutlets for 2-Prong Plug PlugSymbology 25’ 50’ 75’ 100’ 150’Specifications UnpackingInstructions for putting into use FunctionsTool Set Up Cutting Depth AdjustmentInstalling Bits Operating InstructionsEdge Guide Work Piece and Work Area Set Up Dust Extraction AdapterGeneral Operating Instructions For technical questions, please call Maintenance Servicing Cleaning, Maintenance, LubricationTroubleshooting Problem Possible Causes Likely SolutionsParts List Part Description QtyRecord Product’s Serial Number Here Limited 90 DAY Warranty