3Com 3C13840, 3C13880 manual Installing the Generic Modules, Connecting the Pgnd

Page 23

3Com Router 6000 Family

Chapter 4

Installation Manual

Starting and Configuring the Router

(2)

(1)

(3)

(1)(2)

1)

Mounting screws

2) Mounting brackets (with cable-management brackets installed)

3)

Guides

 

Figure 3-2Mount the router in a rack

3.3.2 Mounting the Router on a Tabletop

When mounting the router on a tabletop, ensure that the surface is clean and you have considered the following:

z

z

z

The table is sturdy and well grounded.

10 cm (3.9 in.) clearance is available around the sides of the chassis for heat dissipation.

Do not place any heavy object on the chassis.

3.4 Installing the Generic Modules

Installing generic modules includes installing the main control board, PSUs, the fan module, and FICs.

Refer to the chapter “FICs” for the FIC installation procedures and the chapter “Maintaining Hardware” for the installation procedures of other modules.

3.5 Connecting the PGND

Warning:

The normal connection of the protection ground (PGND) on the router chassis is an essential safeguard against lightning shocks and interference. You must correctly connect the PGND when installing or using the router.

As shown in the following figure, the router provides a protection ground (PGND) screw at the top right-rear of the chassis. You must securely connect it to the earth ground to safely channel faradic current and leakage electricity to the ground and have the device less susceptible to

3Com Corporation

3-3

Image 23
Contents 3C13840 3C13880 3Com Router 6000 Family Installation Guide3Com Corporation Campus Drive Marlborough, MA 01752-3064 Table of Contents Starting and Configuring the Router Components of Integrated Anchor Strips Abundant FIC options II. Ethernet accessRouter Overview IntroductionVI. Online software upgrading VII. Abundant fault isolation methodsData security and reliability VIII. Regulatory compliance Router Model and Structure1 3Com Router Front panel of the 3Com Router 2 3Com Router6040 6080 System Description1 RPU2 SpecificationsSpecifications Generic ModulesLED and button Description II. LED and buttonIII. Interface II. Appearance 2 PSUIV. Encryption daughter card FunctionsIII. LED FAN module11FAN module the 3Com Router FICsGeneral Site Requirements Preparing for InstallationTemperature and Humidity CleannessGas Max. mg/m ESD PreventionElectromagnetic Compatibility Checking the Rack Safety PrecautionsLightning Protection Name Quantity Description Unpacking CheckInstallation Tools and Meters and Equipment Installation Flow Installing The RouterRack-Mounting the Router Installing the Cabinet/RackModel Dimensions Mounting the RouterMounting the Router on a Tabletop Installing the Generic ModulesConnecting the Pgnd AC-input power supply Connecting the Power CordConnecting the AC-Input Power Cord DC-input power supply Connecting the DC-Input Power CordII. AC power socket recommended III. Connecting the AC-input Power CordConsole port Connecting the Console TerminalII. Connecting the DC-input power cord Power source Router sideII. Ethernet cable Connecting the Router to a LANIII. Connecting the console cable Ethernet interfaceIII. Connecting the Ethernet cable Connecting the Router to a WAN II. AUX cable Verifying InstallationIII. Connecting the AUX cable AUX portII. Setting terminal parameters Starting and Configuring the RouterSetting up a Configuration Environment Connecting the router to a console terminal3Com Router 6000 Family Chapter Installation Manual 3Com Router 6000 Family Chapter Installation Manual 5Set the terminal type II. Powering on the router Powering on the RouterBoot Process of the RPU2 Checking before power-onPress Enter. The console screen displays Characteristics of the command line interface Router Configuration BasicsBasic Configuration Procedures Command Line InterfaceArranging Slots and Numbering Interfaces II. Command line interface3Com Router 6000 Family Chapter Installation Manual Maintaining Software of the RPU2 Boot MenuMaintaining Software Overview=BACKUP =SECURE Set this file as Main Backup Exit Enter your choice1-3 Upgrading Software Using Xmodem 1Set Send File parameters Upgrading the application imageThen, the system asks you to select a file type III. Upgrading the extended segment of the Boot ROM image II. Upgrading the entire Boot ROM programEnter Y. The system displays Parameter Description Upgrading the Application Image Using TftpDealing with a Router Password Loss Removing a PSU Removing/Installing PSUsMaintaining Hardware Preparing ToolsRemoving the Fan Module Removing/Installing the Fan ModuleInstalling a PSU Removing the RPU2 Removing/Installing the Main Control BoardInstalling the Fan Module Replacing the Sdram Installing the RPU2II. Removing the Sdram Removing the RPURemoving the Encryption Daughter Card Removing/Installing the Encryption Daughter CardIII. Installing an Sdram IV. Installing the RPU8Install the encryption daughter card Installing the Encryption Daughter CardTroubleshooting the Configuration System TroubleshootingTroubleshooting the Power System Troubleshooting Application Image Upgrade DownLoad Program To Flash Through Net Port Boot Device 3Com Corporation Planning the Site Installing B68 CabinetsInstallation Requirements and Procedures 2Footprint of the combined cabinets General Installation ProceduresComponents of Integrated Anchor Strips Mounting Cabinets on the Concrete Floor5Installing the mounting fixtures onto the anchor strip Installation FlowMarking Positioning Cabinets8Layout of the mounting holes and cabinet feet two cabinets II. Drilling holes III. Installing expansion boltsAdjusting Cabinet Feet 10Lock cabinet feet Combining Cabinets11Remove/install the cover Fixing Cabinets Installing anchor stripsIII. Fixing the retaining nuts of the anchor strips Testing Insulation15Install a single cabinet on the concrete floor Introduction to Racks Mounting Cabinets on the Antistatic FloorII. Shape of racks Number of racks in useComponent Height of antistatic floor mm III. Installing rack componentsIntroduction to Slide Rails 19Dimensions of slide rail segmentsII. Marking Determining where to install the cabinetPositioning Racks 21Layout of the installation holes on the H800 series racks 23Layout of the mounting holes and cabinet feet two cabinets III. Drilling holes II. Adjusting rack height Installing RacksInstalling expansion tubes and nuts Installing T-shape nuts Installing Slide RailsIII. Installing and fixing racks 27 T-shape nut II. Leveling and fixing rails28Fix and level slide rails and racks Installing Antistatic Floor SupportsII. Installing the supports for the antistatic floor II. Leveling the cabinets Leveling CabinetsMoving the cabinets to the position 32Level cabinets III. Locking cabinet feet33Fasten cabinet feet 34Remove/install the cover III. Installing insulating parts and fixing anchor strips Installing the T-shape nutsII. Installing anchor strips 37Fix anchor strips IV. Fixing the retaining nuts of the anchor stripsRestoring the Floor 17illustrates how to install cabinets on the concrete floor39B68 cabinets installed on the antistatic floor
Related manuals
Manual 187 pages 50.8 Kb

3C13840, 3C13880 specifications

The 3Com 3C13880 and 3C13840 are notable components within the realm of networking technology, primarily designed for enterprise-grade solutions. These devices belong to the 3Com family, which has long been recognized for its commitment to developing robust networking products tailored to facilitate efficient data transfers and improve connectivity across various platforms.

One of the standout features of the 3C13880 is its high-performance capabilities. This model supports advanced functions such as load balancing and fault tolerance, critical for maintaining optimum network performance in high-demand environments. Additionally, it supports various protocols, including Ethernet and Token Ring, making it versatile and adaptable to existing infrastructure. The device accommodates a wide range of network transmissions, ensuring seamless integration and operation within diverse network ecosystems.

In terms of connectivity, the 3C13880 is equipped with multiple ports, allowing for extensive device interconnectivity. This feature is particularly beneficial in large organization settings, where multiple devices, such as servers and workstations, need to communicate effectively. Coupled with high-speed data transmission rates, this model ensures minimal latency, enhancing overall network efficiency.

On the other hand, the 3C13840 is designed with a focus on cost-efficiency without sacrificing performance. This model provides essential networking features suitable for smaller business environments or those seeking budget-friendly options. It delivers reliable throughput and the ability to support a moderate number of users, making it ideal for small to mid-sized offices.

Both the 3C13880 and 3C13840 incorporate technologies that prioritize security and reliability. Features such as VLAN support and QoS settings help optimize network performance while ensuring the security and integrity of data are maintained. The devices also support management tools that allow administrators to monitor network performance in real time, facilitating quick troubleshooting and enhancing overall network management.

In summary, both the 3Com 3C13880 and 3C13840 devices stand out in networking technology by offering unique features tailored to different organizational needs. While the 3C13880 appeals to enterprises needing high performance and robust capabilities, the 3C13840 provides an accessible option for those requiring effective and budget-conscious networking solutions. The legacy of 3Com continues to be evident in these products, reflecting their innovative approach to addressing the dynamic demands of modern networking.