Sanyo RCS-KR1EG: Efficient Temperature Control Solutions

Page 10

GU Type Heat Exchanger

CFR Units

 

 

SANYO’s new heat recovery ventilation system allows total control via a system network whilst modulating the temperature and humidity of incoming air supply.

Integration of heat recovery ventilation and DX coil technology for optimum air temperature control

The DX coil can be connected to all ECO & GHP outdoor units

Easy to clean filter

Compact design

Filter option

3 Way: Solenoid valve kit is required for each unit

2 Way: RAP kit is required for each unit

Controller Options

 

 

 

Installation example

 

 

 

 

 

Timer remote controller

Wireless remote controller

 

Simplified remote controller

Humidification DX coil

Heat exchanger

 

 

 

 

 

 

 

 

 

(optional)

 

 

 

 

 

 

RCS-TM80BG

 

RCS-BH80BG.WL

 

Supply air

 

 

 

 

 

 

 

 

 

 

 

Exhaust air

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RCS-KR1EG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return air

 

 

 

 

 

 

 

 

 

 

 

Fresh air

 

 

Indoor unit specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model Name

 

 

 

 

SPW-GU055XH

 

 

SPW-GU075XH

 

 

SPW-GU105XH

 

 

 

 

 

 

 

 

 

 

 

 

Air circulation (H)  m³/h

 

 

 

500

 

750

 

 

 

 

1,000

 

 

Power source

 

 

 

 

 

 

220/230/240V, 1 phase - 50 Hz

 

 

 

 

 

 

Fresh air load

UK Cooling 

 

 

kW

5.3 (1.7)*¹

 

8.2 (2.6)*¹

 

 

 

 

10.7 (3.4)*¹

 

 

treatment capacity

UK Heating 

 

 

kW

6.5 (2.3)*¹

 

9.8 (3.5)*¹

 

 

 

 

12.6 (4.6)*¹

 

 

Enthalpy exchange

UK Cooling 

 

 

%

 

 

59

 

 

 

 

 

 

 

 

 

efficiency

UK Heating 

 

 

%

 

 

67

 

 

 

 

 

 

 

 

 

Temp exchange efficiency

 

 

 

 

 

75

 

 

 

 

 

 

 

 

 

Equivalent cooling capacity

 

 

kW

3.6

 

5.6

 

 

 

 

7.3

 

 

 

 

BTU/h

12,000

 

19,000

 

 

 

 

25,000

 

 

 

 

 

 

 

 

 

 

 

 

 

Power input

Cooling 

 

 

kW

0.532

 

0.737

 

 

 

 

0.798

 

 

Heating 

 

 

kW

0.532

 

0.737

 

 

 

 

0.798

 

 

 

 

 

 

 

 

 

 

 

 

Running current

Cooling 

 

 

Amps

2.4

 

3.2

 

 

 

 

3.5

 

 

Heating 

 

 

Amps

2.4

 

3.2

 

 

 

 

3.5

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

 

 

 

 

 

 

 

Sirocco fan

 

 

 

 

 

 

Fan motor

External static pressure-return air  

Pa

183 (170)

 

221 (188)

 

 

 

 

135 (88)

 

 

External static pressure-supply air  

Pa

205 (182)

 

264 (218)

 

 

 

 

176 (137)

 

 

 

 

 

 

 

 

 

 

 

Output

 

 

kW

0.28 (4P)x2

 

 

 

 

 

 

 

 

 

0.35 (4P)x2

 

 

Sound pressure level (C/H)  

 

 

db(A)

46 (Cooling), 47 (Heating)

 

47 (Cooling), 48 (Heating)

 

 

48 (Cooling), 49 (Heating)

 

 

 

Height

 

 

mm

425

 

 

 

 

 

 

 

 

 

450

 

 

 

 

Dimensions

Width

 

 

mm

1785

 

 

 

 

 

 

 

 

 

1903

 

 

 

 

 

Depth

 

 

mm

1000

 

1120

 

 

 

 

1220

 

 

 

Liquid (flare)  

mm (inches)

 

 

6.35 (1/4)

 

 

 

 

 

 

 

 

 

Piping connections

Gas (flare)  

mm (inches)

 

 

12.7 (1/2)

 

 

 

 

 

 

 

 

 

 

Drain piping

 

 

 

 

 

 

 

 

VP-25

 

 

 

 

 

 

Connection duct diameter  

 

 

mm

250

 

 

 

 

 

 

 

 

 

300

 

 

Net weight  

 

 

 

kg

134

 

153

 

 

 

 

168

 

The values in ( ) for the external static pressure and operating sound are for use of booster cable. *1: Heat recovery capacity by heat exchanger. Data subject to change without notice.

The CFR-PHE unit structure is constructed from Aluzink frame work and galvanised steel with 20 mm thick fire resistant acoustic insulation, reducing both weight and sound levels to a minimum. The system is supplied with ducted spigots which can be positioned either at the front or side of the unit to ease installation.

High efficiency heat exchanger

Easy to clean filters

The high efficiency low pressure loss total heat exchanger is made of specially treated paper to enable the unit to be as efficient as 76% during normal operation. This allows system to recover both latent and sensible heat.

Indoor unit specifications

Model CFR/ CFR-PHE

 

33

 

55

 

110

175

220

 

 

 

 

 

 

 

 

 

Nominal air flow *

m3/hr

300

 

620

 

920

1580

1850

External Static Pressure

pa

45

 

55

 

65

70

77

Sound Pressure **

dB(A)

43

 

51

 

50

53

52

Fans

 

 

 

 

 

 

 

 

Power in

Watts

184

 

340

 

294

700

700

Absorbed power

A

0.75

 

1.8

 

2.2

4.4

4.8

Fan speeds

no

 

1

 

 

 

3

 

Insulation Class

 

 

 

 

 

F

 

 

Electrical supply

v/ph/htz

 

 

 

 

230/1/50

 

 

Bioxigen Elements (PHE only)

 

 

 

 

 

 

 

 

Number of elements

 

 

 

2 X C

 

 

2 X F

Electrical supply

v/ph/htz

 

 

 

 

230/1/50

 

 

Power in

Watts

8

 

8

 

8

8

8

Filter

 

 

 

 

 

EU3

 

 

Paper Heat Exchanger

CFR-PHE

 

 

 

 

 

 

 

Temperature Efficiency heating ***

 

76%

 

74%

 

72%

68%

73%

Temperature Efficiency cooling ****

 

62%

 

60%

 

58%

54%

59%

*Nominal air flow

**Sound pressure 1.5 mts from the unit in free field

***Data referred to -50C 80% RH OAT room condition 200C 50% RH

****Data referred to 320C 50% RH OAT room condition 260C 50% RH

17

 

18

Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB

Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB

 

Image 10
Contents Electric VRF Simple to design Ease of installationOff-coil temperature control Easy to positionUnique Sanyo benefits New PAC2 System Design Software SANYO-Installation cost saving design Solenoid Valve BoxSANYO-Comfort control Air Discharge Temperature Control Reduces the running cost of the systemECOi 2 Way features at a glance ECOi 2 Way Heat Pump VRF Inverter Systems ECOi 3 Way features at a glance Solenoid Valve Kit Higher COPs lower running costsProblems ECOi 3 Way Heat Recovery VRF Inverter SystemsIndustry’s smallest changeover boxes fewer locating Wireless remote control VRF Indoor Unit Range for ECOi and GHPOperation system Individual control systems Timer operation Centralised control systemsModel Name GU Type Heat Exchanger CFR UnitsModel CFR/ CFR-PHE 110 175 220