Grizzly G0538 owner manual Base Attachment, Mounting, Dust Collection

Page 14

Base Attachment

The metal base plate needs to be attached to the spindle sander before use.

Components and Hardware Needed:

Qty

Tap Screw M4-0.7 x 12

4

Sander Base Plate

1

To attach the sander base plate:

 

1.Examine the inside of the sander body and remove any loose packing material found.

Note: Loose packing material inside the sander body during operation is an imminent fire hazard.

2.Attach the base plate to the underside of the sander with the included M4-0.7 x 12 tap screws.

Mounting

We strongly recommend mounting the spindle sander to a mounting board or workbench before being used.

Components and Hardware Needed:

Qty

Hex Bolts 14"-20 (length varies)

4

Hex Nuts 14"-20

4

Flat Washers 14"

8

Lock Washers 14"

4

To secure the spindle sander to a benchtop or mounting board:

1.Place the spindle sander on a workbench or mounting board no smaller than 24"W x 18"D.

2.Using the 14" holes in the sander body as a template, drill holes through the mounting board or benchtop as appropriate.

3.Secure the spindle sander to the benchtop or mounting board with 14" hex bolts, wash- ers, lock washers, and hex nuts as shown in Figure 5.

-12-

Figure 5. Mounting the spindle sander.

Dust Collection

To connect a dust collection hose:

1.Fit the 212" dust hose over the dust port shown in Figure 6, and secure in place with a hose clamp.

2.Tug the hose to ensure it does not come off.

Figure 6. Dust port.

DO NOT operate the Model G0538 without an adequate dust collection system. This saw creates substantial amounts of wood dust while operating. Failure to use a dust collec- tion system can result in respiratory illness.

G0538 Oscillating Spindle Sander

Image 14
Contents Model G0538 Oscillating Spindle Sander Page Table of Contents Contact Info IntroductionForeword Machine Data Sheet Other Identification Safety Safety Instructions for MachineryAlways Lock Mobile Bases if Used Before Operating Machinery Safety Instructions for Spindle Sanders Circuit Requirements 110V OperationItems Needed for Set Up SET UPSet Up Safety UnpackingInventory Figure Qty Pre-Installed Components FigureInventory Hardware BagDust Collection Base AttachmentMounting Operations Switch⁄Safety KeySleeve Installation To sand a workpiece To install or replace a sanding sleeveSanding Accessories H5430-H5459 Sanding SleevesSchedule MaintenanceCleaning Symptom Possible Cause Possible Solution ServiceTroubleshooting Quently Wiring Diagram Parts BreakdownParts List DescriptionWarranty and Returns Page Page