Grounding

To prevent

WARNING electric shock and death from incorrect grounding wire connection:

Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the power cord plug provided with the tool. Never remove the grounding prong from the plug. Do not use the tool if the power cord or plug is damaged. If damaged, have it repaired by a service facility before use. If the plug will not fit the outlet, have a proper outlet installed by a qualified electrician.

Grounded Tools: Tools with Three

Prong Plugs

3-Prong Plug and Outlet

1.Tools marked with “Grounding

Required” have a three wire cord and three prong grounding plug. The plug must be connected to a properly grounded outlet. If the tool should electrically malfunction or break down, grounding provides a low resistance path to carry electricity away from the user, reducing the risk

of electric shock. (See 3-Prong Plug

and Outlet.)

2.The grounding prong in the plug is connected through the green wire inside the cord to the grounding system in the tool. The green wire in the cord must be the only wire connected to the tool’s grounding system and must never be attached to an electrically “live” terminal. (See 3-Prong Plug and Outlet.)

3.The tool must be plugged into an appropriate outlet, properly installed and grounded in accordance with all codes and ordinances. The plug and outlet should look like those in the preceding illustration. (See 3-Prong

Plug and Outlet.)

4.NOTE: THIS BELT/Disc

SANDER HAS A THREE-PRONG GROUNDED PLUG.

Extension Cords

1.Grounded tools require a three wire extension cord. Double Insulated tools can use either a two or three wire extension cord.

2.As the distance from the supply outlet increases, you must use a heavier gauge extension cord. Using extension cords with inadequately sized wire causes a serious drop in voltage, resulting in loss of power and possible tool damage.

(See Table A.) The smaller the gauge number of the wire, the greater the capacity of the cord. For example, a 14 gauge cord can carry a higher current than a 16 gauge cord. (See Table A.)

SKU 97181

For technical questions, please call 1-800-444-3353.

Page 7

Image 7
Contents 6 belt/disc sander Contents Work area safety General Safety RulesSave This Manual Personal safety Electrical safetyPower tool use and care Vibration Hazard ServiceV e t h e s e instructions Specific Safety RulesOutlet GroundingProng Plugs Extension CordsSee Table a Symbology25’ 50’ 75’ Feet Placement SpecificationsInitial Set Up Instructions AssemblyMounting Table for use as Disc Sander Mounting Aluminum DiscMounting Table for use as Belt Sander See Figures 6 Mounting Stop PlateOperating Instructions FunctionsCleaning, Maintenance, Lubrication Maintenance ServicingMounting Sanding Discs Belt Replacement Sanding Belt ReplacementPort 59 after cleaning and tighten Screw Problem Possible Causes Likely Solutions TroubleshootingBelt Tensioning Record Product’s Serial Number Here Please Read the Following CarefullyPart Description ’ty Parts ListAssembly Diagram Limited 1 year / 90 Day warranty