Sanyo SAP-KRV123EH, SAP-KRV93EH Operation with the Remote Control Unit, Automatic Operation, Step

Page 12

01_SAP-KRV93EH_EN.fm Page 12 Thursday, February 12, 2004 12:10 PM

1. Automatic Operation

NOTE

Operation with the Remote Control Unit

This unit automatically switches between cooling operation and heating operation according to the difference between the room temperature and the temperature setting.

STEP 2

STEP 1

Check that the circuit breaker on the power panel is turned on.

Once mode is selected and the unit is preset by following the steps below, you can have the air conditioner automatically bring the room to the desired temperature simply by pressing the ON/OFF operation button.

STEP 1 Press the MODE selector button to .

STEP 2

Press the ON/OFF operation button.

NOTE

To stop the air conditioner, press the ON/OFF operation button again.

To change the temperature setting; press the temperature setting buttons and change the setting to the desired temperature.

12

OI-671-12-EG

 

Image 12
Contents SAP-KRV93EH SAP-KRV123EH This air conditioner uses the new refrigerant R410AFeatures Contents Alert SymbolsProduct Information Installation Location Safety InstructionsElectrical Requirements Names of Parts Indoor UnitOutdoor Unit Unit Display and Operation Button Remote Control Unit Display Remote Control Unit Hour OFF TimerOn Time Auto HeatDRY CoolUsing the Remote Control Unit Temperature Display SelectorHow to Install Batteries Button Time Display Selector buttonUsing the Remote Control Unit Operation with the Remote Control Unit Automatic OperationStep Press the ON/OFF operation buttonOperation with the Remote Control Unit Manual OperationAdjusting the Fan Speed Fan OnlyNight Setback Mode Quiet Mode High Power ModeRemote Control Unit Special Remarks‘‘DRY’’ Operation Heating OperationSetting the Timer How to set the present timeOperation Indication Setting the Timer How to set Daily ON/OFF Repeat timerTo cancel a timer program Press the Cancel button 1030 pm 710 am 1100 am Present timeUsing the 1-Hour OFF Timer Setting procedureCancellation procedure Operation together with the Daily ON/OFF Repeat TimerAdjusting the Airflow Direction Setting the airflow manuallySweep function Auto flap functionOperation without the Remote Control Unit Care and CleaningWhen the air conditioner is not running Care and Cleaning Air intake grille Anti-mold filter CleaningSuffocation in extreme cases FilterTroubleshooting Operating RangeTrouble Possible Cause Remedy
Related manuals
Manual 77 pages 63.4 Kb

SAP-KRV93EH, SAP-KRV123EH specifications

The Sanyo SAP-KRV93EH and SAP-KRV123EH are innovative air conditioning units that stand out in the market for their performance, energy efficiency, and user-friendly features. Designed to cater to various cooling needs, these models are suitable for both residential and commercial spaces, ensuring comfort in every environment.

One of the main features of both models is their advanced inverter technology. This technology allows the air conditioners to adjust the compressor speed according to the desired temperature, offering precise climate control while significantly reducing energy consumption. This not only translates to lower electricity bills but also minimizes the environmental impact, making the SAP-KRV93EH and SAP-KRV123EH eco-friendly options.

The SAP-KRV93EH has a cooling capacity of 9,000 BTU, while the SAP-KRV123EH boasts an impressive 12,000 BTU. This range ensures that users can choose the appropriate unit according to the size of the room or area requiring cooling. The units are equipped with high-efficiency filters that purify the air, removing dust, allergens, and other particulates. This feature is particularly beneficial for those with allergies or respiratory issues, providing a healthier indoor environment.

In terms of user interface, both models are designed with ease of use in mind. They include a remote control that allows users to adjust settings without needing to get up. Additionally, the units have a programmable timer, ensuring that users can set the air conditioning to operate only when needed, enhancing convenience and energy savings.

Another notable technology present in these models is the “Smart Duct” airflow system. This system optimizes air distribution, allowing for an even distribution of cooled air throughout the room. This means fewer hot spots, leading to a more comfortable living or working space.

Both the SAP-KRV93EH and SAP-KRV123EH have sleek designs that blend well with various interior styles, allowing them to fit seamlessly into homes or offices. Furthermore, they operate quietly, ensuring that users can enjoy a peaceful environment.

Overall, the Sanyo SAP-KRV93EH and SAP-KRV123EH air conditioning units combine advanced technology, energy efficiency, and practical features, making them an excellent choice for those looking to enhance their comfort while being conscious of energy usage. With their robust performance and user-friendly attributes, these models epitomize what modern air conditioning solutions should offer.