Sanyo SAP-KRV123EH, SAP-KRV93EH Operation without the Remote Control Unit, Care and Cleaning

Page 22

01_SAP-KRV93EH_EN.fm Page 22 Thursday, February 12, 2004 12:10 PM

Operation without the Remote

Control Unit

INDOOR UNIT

If you have lost the remote control unit or it has trouble, follow the steps

 

below.

When the air conditioner is not running

Each time the OPERATION button is pressed, the type of operation conducted is indicated by the changing color of the OPERATION lamp. Press the button and select the lamp color that suits your preference for operation.

Cooling operation

 

Heating operation

 

Stop

 

 

(green)

 

(red)

 

(lamp off)

OPERATION button

NOTE

The temperature is set to the room temperature minus 2°C during the cooling operation and to the room temperature plus 2°C during the heating operation, and the fan speed and flap are set to Auto.

Care and Cleaning

1. For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning.

2.Do not pour water on the indoor unit to clean it. This will damage the internal components and cause an electric shock hazard.

Casing and Grille (Indoor Unit) Clean the casing and grille of the indoor unit with a vacuum cleaner brush, or wipe them with a clean, soft cloth.

If these parts are stained, use a clean cloth moistened with a mild liquid detergent. When cleaning the grille, be careful not to force the vanes out of place.

CAUTION

1.Never use solvents, or harsh chemicals when cleaning the indoor unit. Do not wipe the plastic casing using very hot water.

2.Some metal edges and the fins are sharp and may cause injury if handled improperly; be especially careful when you clean these parts.

3.The internal coil and other components of the outdoor unit must be cleaned every year. Consult your dealer or service center.

22

OI-671-22-EG

 

Image 22
Contents SAP-KRV93EH SAP-KRV123EH This air conditioner uses the new refrigerant R410AFeatures Alert Symbols ContentsProduct Information Safety Instructions Installation LocationElectrical Requirements Indoor Unit Names of PartsOutdoor Unit Unit Display and Operation Button Remote Control Unit Display Hour OFF Timer Remote Control UnitOn Time DRY AutoHeat CoolHow to Install Batteries Using the Remote Control UnitTemperature Display Selector Button Time Display Selector buttonUsing the Remote Control Unit Step Operation with the Remote Control UnitAutomatic Operation Press the ON/OFF operation buttonOperation with the Remote Control Unit Manual OperationAdjusting the Fan Speed Fan OnlyNight Setback Mode Quiet Mode High Power Mode‘‘DRY’’ Operation Remote Control UnitSpecial Remarks Heating OperationHow to set the present time Setting the TimerOperation Indication To cancel a timer program Press the Cancel button Setting the TimerHow to set Daily ON/OFF Repeat timer 1030 pm 710 am 1100 am Present timeCancellation procedure Using the 1-Hour OFF TimerSetting procedure Operation together with the Daily ON/OFF Repeat TimerSweep function Adjusting the Airflow DirectionSetting the airflow manually Auto flap functionCare and Cleaning Operation without the Remote Control UnitWhen the air conditioner is not running Care and Cleaning Air intake grille Anti-mold filter CleaningSuffocation in extreme cases FilterOperating Range TroubleshootingTrouble Possible Cause Remedy
Related manuals
Manual 77 pages 63.4 Kb

SAP-KRV93EH, SAP-KRV123EH specifications

The Sanyo SAP-KRV93EH and SAP-KRV123EH are innovative air conditioning units that stand out in the market for their performance, energy efficiency, and user-friendly features. Designed to cater to various cooling needs, these models are suitable for both residential and commercial spaces, ensuring comfort in every environment.

One of the main features of both models is their advanced inverter technology. This technology allows the air conditioners to adjust the compressor speed according to the desired temperature, offering precise climate control while significantly reducing energy consumption. This not only translates to lower electricity bills but also minimizes the environmental impact, making the SAP-KRV93EH and SAP-KRV123EH eco-friendly options.

The SAP-KRV93EH has a cooling capacity of 9,000 BTU, while the SAP-KRV123EH boasts an impressive 12,000 BTU. This range ensures that users can choose the appropriate unit according to the size of the room or area requiring cooling. The units are equipped with high-efficiency filters that purify the air, removing dust, allergens, and other particulates. This feature is particularly beneficial for those with allergies or respiratory issues, providing a healthier indoor environment.

In terms of user interface, both models are designed with ease of use in mind. They include a remote control that allows users to adjust settings without needing to get up. Additionally, the units have a programmable timer, ensuring that users can set the air conditioning to operate only when needed, enhancing convenience and energy savings.

Another notable technology present in these models is the “Smart Duct” airflow system. This system optimizes air distribution, allowing for an even distribution of cooled air throughout the room. This means fewer hot spots, leading to a more comfortable living or working space.

Both the SAP-KRV93EH and SAP-KRV123EH have sleek designs that blend well with various interior styles, allowing them to fit seamlessly into homes or offices. Furthermore, they operate quietly, ensuring that users can enjoy a peaceful environment.

Overall, the Sanyo SAP-KRV93EH and SAP-KRV123EH air conditioning units combine advanced technology, energy efficiency, and practical features, making them an excellent choice for those looking to enhance their comfort while being conscious of energy usage. With their robust performance and user-friendly attributes, these models epitomize what modern air conditioning solutions should offer.