9.TROUBLESHOOTING
| PROBLEM | REASON | SOLUTION |
|
|
|
|
| Red LED is on, | Poor contact at | Unplug and reinsert the 12V |
| audible alarm | terminals. | plug or check connections at |
| is on, and/or |
| power supply. |
| converter does | Fuse blown. | See “IF THE Converter |
| not function. | ||
|
|
| FUSE BLOWS” section. |
|
| Converter | See “LED INDICATOR |
|
| shutdown. | AND SHUTDOWN |
|
|
| PROTECTION” section. |
|
| Converter may | See Warranty and contact |
|
| not be working | Customer Service. |
|
| properly. |
|
|
|
|
|
|
|
|
|
| 10. SPECIFICATIONS |
| |
| Maximum Continuous Power | 410 Watts | |
| Surge Capability (Peak Power) | 820 Watts | |
| No Load Current Draw | <0.5A | |
| Wave Form |
| Modified Sine Wave |
| Input Voltage Range | ||
| Output Voltage Range | 120V ± 5% AC | |
| Low Battery Alarm | Audible, 11V ± 0.3V DC | |
| Low Battery Shutdown | 10.5V ± .3V DC | |
| High Battery Shutdown | 15.5V ± 0.5V DC | |
| Optimum Efficiency | 85% | |
| AC Outlet |
| Two, NEMA |
| USB Port |
| One, 5V DC 2.1A |
| Fuse |
| Two, 25A (Spade Type) |
| Dimensions |
| 6.5" L x 4.13" W x 2.2" H |
| Weight |
| approximately 2 lbs. |
• 10 •