4.The case temperature becomes hot (exceeds 145°F). The Green and Red LEDs are on, with a buzzer. Solution: Allow the converter to cool. Do not block the cooling slots or air flow over and through the converter. Reduce the load on the converter to the continuous rated output.
RESET: To reset after shutdown occurs:
1.Disconnect the converter from the 12V power source.
2.Check the source of the problem and correct.
3.Reconnect the converter to the 12V power source. NOTE: If the red LED is lit and the green LED is not, see the Troubleshooting section.
8.IF THE CONVERTER FUSE BLOWS
Your power converter is fitted with a fuse, which should not have to be replaced under normal operating conditions. A blown fuse is usually caused by reverse polarity or a short circuit within the device or equipment being operated.
If the fuse does blow:
1.Disconnect the device or equipment immediately.
2.Find the source of the problem and repair it.
3.Install a new fuse (25A). The fuse can be found on the back of the converter.
Do not install a fuse with a higher amp rating than the original fuse, as this may damage the converter and any product you use with the converter. Make sure to correct the cause of the blown fuse before using the converter again.
• 9 •