8.battery charging - ac connections

8.1For grounded, cord-connected battery chargers with an input rating less than 15 amperes and intended for use on a nominal 120-volt circuit:

This battery charger is for use on a nominal 120-volt circuit, and has a grounding plug that looks like the plug illustrated in sketch A in Figure 8.3. A temporary adapter, which looks like the adapter illustrated in sketches B and C, may be used to connect this plug to a two-pole recep- tacle as shown in sketch B if a properly grounded outlet is not available. The temporary adapter should be used only until a properly grounded outlet can be installed by a qualified electrician.

DANGER – Before using adapter as illustrated, be certain that center screw of outlet plate is grounded. The green-colored rigid ear or lug ex tending from adapter must be connected to a properly grounded outlet– make certain it is grounded. If necessary, replace original outlet cover plate screw with a longer screw that will secure adapter ear or lug to out- let cover plate and make ground connection to grounded outlet.Recom- mended minimum awg size for extension cords for battery chargers:

8.2

AWG Size of Cord

25

50

100

150

Length of Cord, Feet

18

18

18

16

8.3

Grounding Methods