Symptom-to-FRU index
The
Note: Do the FRU replacement or other actions in the sequence shown in the column headed ″FRU or action, in Sequence″. If replacing a FRU does not solve the problem, put the original part back in the computer. Do not replace a
This index can also help you determine, during regular servicing, what FRUs are likely to need to be replaced next.
A numeric error is displayed for each error detected in POST or system operation. In the displays, n can be any number.
If no numeric code is displayed, check the narrative descriptions of symptoms. If the symptom is not described there, go to “Intermittent problems” on page 52.
Note: For an IBM devices not supported by diagnostic codes in the ThinkPad notebook computers, see the manual for that device.
Numeric error codes
Symptom or error | FRU or action, in sequence | ||
|
|
| |
0175 | 1. | System board. | |
| |||
Bad CRC1, stop POST task. |
|
| |
The EEPROM checksum is not |
|
| |
correct. |
|
| |
|
|
| |
0187 | 1. | System board. | |
| |||
EAIA data access error |
|
| |
|
|
| |
0190 | 1. Critical low battery error. | ||
| |||
Critical low battery error. |
| Charge the battery pack. | |
2. | Battery pack. | ||
| |||
|
|
| |
0193 | 1. | Enter the supervisor | |
| |||
RF antenna has been removed. |
| password. | |
|
| ||
|
|
| |
0194The computer has been | 1. | Enter the supervisor | |
carried through a security gate. | |||
| password. | ||
|
| ||
|
|
|