02F4 | 1. | Load Setup Defaults in |
| ||
EISA CMOS not writable. |
| IBM BIOS Setup |
| Utility.Replace the backup | |
|
| |
|
| battery. |
| 2. | System board. |
|
|
|
02F5 | 1. | DIMM. |
| ||
DIMM test failure | 2. | System board. |
|
| |
|
|
|
02F6 | 1. | DIMM. |
| ||
Software NMI failure | 2. | System board. |
|
| |
|
|
|
02F7 | 1. | DIMM. |
| ||
2. | System board. | |
|
| |
|
|
|
Error messages
Symptom or error | FRU or action, in sequence | ||
|
|
| |
Device address conflict | 1. | Load Setup Defaults in | |
| |||
|
| IBM BIOS Setup Utility. | |
| 2. | Backup battery. | |
| 3. | System board. | |
|
|
| |
Allocation error for device | 1. | Load Setup Defaults in | |
| |||
|
| IBM BIOS Setup Utility. | |
| 2. | Backup battery. | |
| 3. | System board. | |
|
|
| |
Failing bits: nnnn | 1. | DIMM. | |
| |||
| 2. | System board. | |
|
|
| |
Invalid system configuration | 1. | DIMM. | |
data | |||
2. | System board. | ||
| |||
|
|
| |
I/O device IRQ conflict | 1. | Load Setup Defaults in | |
| |||
|
| IBM BIOS Setup Utility. | |
| 2. | Backup battery. | |
| 3. | System board. | |
|
|
| |
Operating system not found | 1. | Enter IBM BIOS Setup | |
| |||
|
| Utility and see whether | |
|
| the hard disk drive and | |
|
| the diskette drive are | |
|
| properly identified. | |
| 2. | Diskette drive. | |
| 3. | Hard disk drive. | |
| 4. | System board. | |
|
|
|