Error Reporting and Handling

Intel® Server Board SE7520JR2

 

 

 

 

Error Code

Error Message

 

Response

8130

Processor 01 disabled

 

Warning

8131

Processor 02 disabled

 

Warning

8140

Processor 01 failed FRB-3 timer

 

Warning

8141

Processor 02 failed FRB-3 timer

 

Warning

8150

Processor 01 failed initialization on last boot.

 

Warning

8151

Processor 02 failed initialization on last boot.

 

Warning

8160

Processor 01 unable to apply BIOS update

 

Pause

8161

Processor 02 unable to apply BIOS update

 

Pause

8170

Processor 01 failed BIST

 

Pause

8171

Processor 02 failed BIST

 

Pause

8180

BIOS does not support current stepping for Processor 1

 

Pause

8181

BIOS does not support current stepping for Processor 2

 

Pause

8190

Watchdog timer failed on last boot

 

Warning

8198

OS boot watchdog timer failure

 

Pause

8300

BaseBoard Management Controller failed Self Test

 

Pause

8301

Not enough space in Runtime area!!. SMBIOS data will not be available.

Pause

8305

Primary Hot swap Controller failed to function

 

Pause

84F1

BIST failed for all available processors

 

Halt

84F2

BaseBoard Management Controller failed to respond

 

Pause

 

 

 

 

84F3

BaseBoard Management Controller in Update Mode

 

Pause

 

 

 

 

84F4

Sensor Data Record Empty

 

Pause

 

 

 

 

84FF

System Event Log Full

 

Warning

 

 

 

 

8500

Bad or missing memory in slot 3A

 

Pause

 

 

 

 

8501

Bad or missing memory in slot 2A

 

Pause

 

 

 

 

8502

Bad or missing memory in slot 1A

 

Pause

 

 

 

 

8504

Bad or missing memory in slot 3B

 

Pause

 

 

 

 

8505

Bad or missing memory in slot 2B

 

Pause

 

 

 

 

8506

Bad or missing memory in slot 1B

 

Pause

 

 

 

 

8600

Primary & Secondary BIOS ID's don't match.

 

Pause

 

 

 

8601

Override Jumper is set to force boot from lower bank of flash ROM.

Pause

 

 

 

 

8602

WatchDog Timer Expired(Secondary BIOS maybe bad!).

 

Pause

 

 

 

 

8603

Secondary BIOS CheckSum fail.

 

Pause

 

 

 

 

The following table indicates error codes that are sent to the Management Module for error logging as a BMC pass-through command. All commands are of “Error” type. The syntax of error logging with the management module and SEL is different. The same error is logged differently in the SEL than with the Management Module.

 

 

 

 

Table 69: Error Codes Sent to the Management Module

 

 

 

 

 

 

 

 

Error code

Error messages

 

 

161

 

Bad CMOS Battery

 

 

 

 

 

 

 

301

 

Keyboard failure

 

 

102

 

System Board failure ( Timer tick 2 test failure)

 

 

 

 

 

 

 

106

 

Diskette Controller Failure

 

 

604

 

Diskette Drive ? failure

 

 

 

 

 

 

 

163

 

Time of the day not set

 

 

 

 

 

 

01298000

The BIOS does not support the current stepping of Processor P0

 

 

 

 

 

 

01298001

The BIOS does not support the current stepping of Processor P1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

164

 

Revision 1.0

 

 

 

 

 

C78844-002