Platform Management

 

 

 

Intel® Server Board SE7520JR2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensor #

Sensor

Event /

Event Offset

Assert /

Readable

 

PEF

SDR

Sensor Name

Reading

Event Data

Record

Type

Triggers

Deassert

Value/Offsets

Action

 

 

Type

 

Type

Tach Fan 6

20h

Fan

Threshold

[u,l][ c,nc]

As & De

Analog

R, T

Fault LED

01

04h

01h

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tach Fan 7

21h

Fan

Threshold

[u,l][ c,nc]

As & De

Analog

R, T

Fault LED

01

04h

01h

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tach Fan 8

22h

Fan

Threshold

[u,l][ c,nc]

As & De

Analog

R, T

Fault LED

01

04h

01h

Action

 

 

 

 

 

 

 

 

Tach Fan 9

23h

Fan

Threshold

[u,l][ c,nc]

As & De

Analog

R, T

Fault LED

01

04h

01h

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Processor

Sensor

 

 

 

 

 

 

Proc1

IERR

24h

Specific

IERR

As

–

Trig Offset

–

02

07h

 

 

 

6Fh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Processor

Sensor

 

 

 

 

 

 

Proc2

IERR

25h

Specific

IERR

As

–

Trig Offset

–

02

07h

 

 

 

6Fh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Processor

Sensor

 

 

 

 

Fault LED

 

Proc1 Thermal trip

26h

Specific

Thermal Trip

As

–

Trig Offset

02

07h

Action

 

 

 

6Fh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Processor

Sensor

 

 

 

 

Fault LED

 

Proc2 Thermal trip

27h

Specific

Thermal Trip

As

–

Trig Offset

02

07h

Action

 

 

 

6Fh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Proc1 Throttle

28h

Temp

Threshold

[u,l][ c,nc]

As & De

Analog

Trig Offset

Fault LED

01

01h

01h

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Proc2 Throttle

29h

Temp

Threshold

[u,l][ c,nc]

As & De

Analog

Trig Offset

Fault LED

01

01h

01h

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Diagnostic Interrupt

 

Critical

Sensor

 

 

 

 

 

 

2Ah

Interrupt

Specific

FP NMI Button

As

–

Trig Offset

NMI Pulse

02

Button

 

 

 

13h

6Fh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chassis Identify

 

Button

Generic

Sate

 

 

 

ID LED

 

2Bh

Deasserted

As & De

–

Trig Offset

02

 

Button

 

14h

03h

 

Action

 

 

State Assert

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Proc1 Fan

2Ch

Fan

Threshold

[u,l][ c,nc]

As & De

Analog

R, T

Fault LED

01

04h

01h

Action

 

 

 

 

 

 

 

 

Proc2 Fan

2Dh

Fan

Threshold

[u,l][ c,nc]

As & De

Analog

R, T

Fault LED

01

04h

01h

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Proc1 Core temp

2Eh

Temp

Threshold

[u,l][ c,nc]

As & De

Analog

R, T

Fault LED

01

01h

01h

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Proc2 Core temp

2Fh

Temp

Threshold

[u,l][ c,nc]

As & De

Analog

R, T

Fault LED

01

01h

01h

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPU Configuration

30h

Processor

Generic

State Asserted

As & De

Discrete

R, T

Fault LED

02

Error

 

07h

03h

Action

 

 

 

 

 

 

 

OEM Type 53h

-

OEM Type

N/A

N/A

N/A

N/A

N/A

N/A

N/A

53h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 