Platform Management

 

 

 

Intel® Server Board SE7520JR2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensor #

Sensor

Event /

Event Offset

Assert /

Readable

 

PEF

SDR

Sensor Name

Reading

Event Data

Record

Type

Triggers

Deassert

Value/Offsets

Action

 

 

Type

 

Type

Tach Fan 6

20h

Fan

Threshold

[u,l][ c,nc]

As & De

Analog

R, T

Fault LED

01

04h

01h

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tach Fan 7

21h

Fan

Threshold

[u,l][ c,nc]

As & De

Analog

R, T

Fault LED

01

04h

01h

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tach Fan 8

22h

Fan

Threshold

[u,l][ c,nc]

As & De

Analog

R, T

Fault LED

01

04h

01h

Action

 

 

 

 

 

 

 

 

Tach Fan 9

23h

Fan

Threshold

[u,l][ c,nc]

As & De

Analog

R, T

Fault LED

01

04h

01h

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Processor

Sensor

 

 

 

 

 

 

Proc1

IERR

24h

Specific

IERR

As

Trig Offset

02

07h

 

 

 

6Fh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Processor

Sensor

 

 

 

 

 

 

Proc2

IERR

25h

Specific

IERR

As

Trig Offset

02

07h

 

 

 

6Fh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Processor

Sensor

 

 

 

 

Fault LED

 

Proc1 Thermal trip

26h

Specific

Thermal Trip

As

Trig Offset

02

07h

Action

 

 

 

6Fh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Processor

Sensor

 

 

 

 

Fault LED

 

Proc2 Thermal trip

27h

Specific

Thermal Trip

As

Trig Offset

02

07h

Action

 

 

 

6Fh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Proc1 Throttle

28h

Temp

Threshold

[u,l][ c,nc]

As & De

Analog

Trig Offset

Fault LED

01

01h

01h

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Proc2 Throttle

29h

Temp

Threshold

[u,l][ c,nc]

As & De

Analog

Trig Offset

Fault LED

01

01h

01h

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Diagnostic Interrupt

 

Critical

Sensor

 

 

 

 

 

 

2Ah

Interrupt

Specific

FP NMI Button

As

Trig Offset

NMI Pulse

02

Button

 

 

 

13h

6Fh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chassis Identify

 

Button

Generic

Sate

 

 

 

ID LED

 

2Bh

Deasserted

As & De

Trig Offset

02

 

Button

 

14h

03h

 

Action

 

 

State Assert

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Proc1 Fan

2Ch

Fan

Threshold

[u,l][ c,nc]

As & De

Analog

R, T

Fault LED

01

04h

01h

Action

 

 

 

 

 

 

 

 

Proc2 Fan

2Dh

Fan

Threshold

[u,l][ c,nc]

As & De

Analog

R, T

Fault LED

01

04h

01h

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Proc1 Core temp

2Eh

Temp

Threshold

[u,l][ c,nc]

As & De

Analog

R, T

Fault LED

01

01h

01h

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Proc2 Core temp

2Fh

Temp

Threshold

[u,l][ c,nc]

As & De

Analog

R, T

Fault LED

01

01h

01h

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPU Configuration

30h

Processor

Generic

State Asserted

As & De

Discrete

R, T

Fault LED

02

Error

 

07h

03h

Action

 

 

 

 

 

 

 

OEM Type 53h

-

OEM Type

N/A

N/A

N/A

N/A

N/A

N/A

N/A

53h

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

140

Revision 1.0

 

C78844-002