Platform Management

Intel® Server Board SE7520JR2

5.2.1Server Management I2C Buses

The table below describes the server management I2C bus assignments and lists the devices that are connected to the indicated bus. The column labeled “I2C Bus ID” represents the physical I2C bus connected to the mBMC. Only the Peripheral SMBus is available for use with the Write-Read I2C IPMI command.

Table 46: Server Management I2C Bus ID Assignments

I2C Bus ID

Bus Name

Devices Connected

1

Host SMBus

SMBus, PCI slots, ICH5, mBMC, DIMM FRU

 

 

 

2

Peripheral SMBus

SMLink, ICH5, mBMC, SIO 3, LM93, control panel, PDB,

Baseboard Temp Sensor, BMC FRU

 

 

 

 

 

4

Private Bus 4 – PB4

Network Interface Chipset

 

 

 

5.2.2Power Control Interfaces

The mBMC is placed between the power button and the chipset so it can implement the Secure Mode feature of disabling the power button, and add additional power control sources to the system. In addition to the mandatory chassis controls, such as power–down and power-up, the mBMC supports power cycle and pulse diagnostic interrupt.

The mBMC Chassis Control command supports the following power behavior.

Power down (0h – Chassis Control command): This option asserts a 4s override to the chipset

Soft Shutdown (5h – Chassis Control command): This option generates a 200ms pulse of the chipset power button

5.2.3External Interface to the mBMC

The following figure shows the data/control flow to and within the functional modules of the mBMC. External interfaces, namely the host system, Lan-On-Motherboard (LOM), and peripherals interact with the mBMC through the corresponding interface modules.

Power supply control functions and control panel control functions are built into the mBMC. The mBMC communicates with the internal modules using its private SMBus. External devices and sensors interact with the mBMC using the peripheral SMBus. LOM communicates through the LOM SMBus.

122

Revision 1.0

 

C78844-002