Intel® Server Board SE7520JR2

Platform Management

5.3.5.4.2Fault / Status LED

The following table shows mapping of sensors/faults to the LED state.

 

 

Table 50: Fault / Status LED

 

 

 

Color

Condition

When

Green

Solid

System ready

 

 

Blink

System ready, but degraded: CPU disabled

 

 

 

 

Amber

Solid

Critical failure: critical fan, voltage, or temperature state

 

 

Blink

Non-critical failure: non-critical fan, voltage, or temperature state

 

 

 

 

Off

Solid

System not ready: POST error / NMI event / CPU or terminator missing

 

 

 

Critical Condition - Any critical or non-recoverable threshold crossing associated with the following events:

Temperature, voltage, or fan critical threshold crossing

Critical Event Logging errors, including System Memory Uncorrectable ECC errors and FSB Bus errors,.

Non-Critical Condition

Temperature, voltage, or fan non-critical threshold crossing

Chassis intrusion

Degraded Condition

One or more processors are disabled by Fault Resilient Boot (FRB)

5.3.5.4.3Chassis ID LED

The Chassis ID LED provides a visual indication of a system being serviced. The state of the Chassis ID LED is toggled by the chassis ID button or it can be controlled by the Chassis Identify command.

 

 

Table 51: Chassis ID LED

 

 

 

Color

Condition

When

Blue

Off

Ok

 

 

Blink

Identify button pressed or Chassis Identify command executed

 

 

 

 

5.3.5.5Control Panel Inputs

The mBMC monitors the control panel switches and other chassis signals. The control panel input buttons are momentary contact switches, which are de-bounced by the mBMC processor firmware. The de-bounce time is 25 ms.

Revision 1.0

129

 

C78844-002