PageF-3
X-Rack Master Module
Use the D-Pot to select ‘le’ (MIDI Remote Learn) and press SAVEto enable learn mode.
Operate any one of the ‘soft’ controls on the XR622 Master module. This will cause the LED of the
selected control to flash (the ‘SEL’ LED will flash if either of the potentiomenters have been chosen).
Assigna MIDI controller to the selected function by operating the required MIDI controller. Repeat the
‘operate – assign’ process for all requiredcontrols.
Pressthe D-Pot again to leave this option and return to the setup menu or press and hold SETUP/MIDI
until the SETUP/MIDI LED stops flashing to return to normal operation.
Switch assignments can be resetto the system defaults by pressing COPY/DEL when in MIDI Remote
Learn mode; the ‘Empty’ LED indicating when the assignments have been deleted.
Note. Theseconfiguration options are also covered in the main X-Rack manual.
Level Compensation
Each of the Insert Send, Mix Bus, RecordBus and Monitor outputs are provided with level compensation
for driving low (600Ω) inputs. Level compensation is activated by removing a jumper for each output as
follows:
Default MIDI Controller Mapping
MIDI Controller Master Module Control
1 MIX
2 REC
3 EXT
4 ALT
5 MONO
6 DIM
7 CUT
8 AFLLevel
9 Monitor LEVEL
600Ω Output Level Compensation
Link Output
LK1 Alt/Main Monitor Right
LK2 Record Bus Left
LK3 Record Bus Right
LK4 Alt/Main Monitor Left
LK5 Insert Send Left
LK6 Insert Send Right
LK7 Mix Bus Left
LK8 Mix Bus Right