X-Rack Dynamics Module
D.3 Performance Specification
The following pages contain audio performance specification figures for the
D.3.1 Measurement Conditions
For each set of figures on the following pages, the specific unit and test setup will be stated at the beginning of that section. Any changes to the specified setup for any particular figure(s) will be detailed beside the figures to which that difference applies.
D.3.2 Measurement References
Unless otherwise specified the references used in this specification are as follows:
• | Reference frequency: | 1kHz |
• | Reference level: | 0dBu, where 0dBu ≈0.775V into any load |
• Source impedance of Test Set: | 50Ω | |
• Input impedance of Test Set: | 100kΩ |
•All unweighted measurements are specified as 22Hz to 22kHz band limited RMS and are expressed in units of dBu
•All distortion measurements are specified with a 36dB/Octave low pass filter at 80kHz and are expressed as a percentage
•The onset of clipping (for headroom measurements) should be taken as 1% THD
•Unless otherwise quoted all figures have a tolerance of ±0.5dB or 5%
•All measurements are made with the operating level switch set for +4dBu
D.3.3 Compressor/Limiter |
|
Controls: |
|
Ratio (slope) | Variable from 1 to infinity (limit) |
Threshold | Variable from +10dB to |
Attack Time | Normally auto sensing, switchable to 1mS |
Release | Variable from 0.1 to 4 seconds |
The XLogic Channel unit Compressor/Limiter has two modes of signal detection, Peak and RMS. As their names suggest these modes of detection either act on peaks of the incoming signals or on their RMS levels. This gives two very different modes of compression and limiting with Peak Mode giving far more dramatic compression characteristics.
D.3.4 Expander/Gate |
|
Controls: |
|
Range | Variable from 0 to 40dB |
Threshold | Variable from |
Attack Time | Normally |
Hold Time | Variable from 0 to 4 seconds |
Release Time | Variable from 0.1 to 4 seconds |
The side chain signal can be sourced either from the signal feeding the dynamic or the external Key input. Filters and/or Equaliser can be inserted in the sidechain.
LED meters independently indicate amount of compression and expansion.