Solid State Logic X-Logic Series owner manual LF EQ Maximum Gain, ‘Balance’ Adaptor, B-6

Models: X-Logic Series

1 58
Download 58 pages 10.04 Kb
Page 36
Image 36

X-Rack Owner’s Manual

LF EQ - Maximum Gain

 

 

Adjustment:

1. Set LF Gain to maximum and select LF

. Set the audio oscillator for

 

80Hz and adjust LF Frequency to find the maximum level on the audio

 

level meter.

 

 

2. Adjust VR14 (LF Q) for +16.5dBu ±0.25dB.

 

 

3.

Reset LF Gain to its centre indent position, de-select LF

and re-check

 

 

the audio level meter for 0dBu.

 

B.4.2

Output Balance

 

 

 

Equipment Required:

Calibrated audio oscillator, audio level meter and a ‘balance’ adaptor (see

 

 

below).

 

 

Test Signal:

1kHz sine wave at +24dBu.

 

 

Input and Output:

Oscillator to the Input of the channel being tested, Output to the level

 

 

meter via the ‘balance’ adaptor.

 

 

Unit Setup:

Ensure that all front panel switches are off and all controls are set fully

 

 

anti-clockwise.

 

 

Adjustment:

Connect the test equipment to the each channel in turn and adjust VR15

 

 

(BAL) for minimum level (< 55dBr).

 

B.4.3

‘Balance’ Adaptor

 

 

For the output balance adjustment, a ‘balance’ adaptor such as that illustrated here will be required. This adaptor consists of a pair of close tolerance resistors in an in-line cable and is used to sum together a balanced output in order to correctly adjust the level balance of the measured output; perfect balance should result in complete signal cancellation.

 

1

 

3

 

 

0V

 

 

 

 

 

1

 

 

 

From unit

2

5K01**

 

 

 

+

 

 

 

To measuring 2

under test

 

1

2

+

 

3

5K01**

 

equipment

 

 

 

1 0V

Note 1. Resistor tolerance should ideally be 0.01%

2.Absolute level measured will depend upon the input impedence of the measuring equipment.

Page B-6