Intel® Server Board SE7520JR2

Platform Management

down, power cycle, and/or reset actions, the actions are performed according to PEF Action Priorities.

Note: An action that has changed from delayed to non-delayed, or an action whose delay time has been reduced automatically has higher priority. The mBMC can be configured to log PEF actions as SEL events.

Table 54: PEF Action Priorities

Action

Priority

Delayed

Type

Note

Power-Down

1

Yes

PEF Action

 

 

 

 

 

 

Soft-shutdown

2

Yes

OEM PEF Action

Not executed if a power-down action was

 

 

 

 

also selected

 

 

 

 

 

Power cycle

3

Yes

PEF Action

Not executed if a power-down action was

 

 

 

 

also selected

 

 

 

 

 

Reset

4

Yes

PEF Action

Not executed if a power-down action was

 

 

 

 

also selected

 

 

 

 

 

Diagnostic Interrupt

5

No

PEF Action

Not executed if a power-down action was

 

 

 

 

also selected

PET Alert

6

No

PEF Action

When selected, always occurs immediately

 

 

 

 

after detection of a critical event.

 

 

 

 

 

Sensor feedback

7

No

OEM PEF Action

When selected, always occurs immediately

 

 

 

 

after detection of a critical event.

 

 

 

 

 

IPMB message event

8

No

OEM PEF Action

When selected, always occurs immediately

 

 

 

 

after detection of a critical event.

 

 

 

 

 

Fault LED action

9

No

OEM PEF Action

When selected, always occurs immediately

 

 

 

 

after detection of a critical event, and is

 

 

 

 

stopped after the de-assertion of all critical

 

 

 

 

events that requested LED blinking.

Identification LED action

10

No

OEM PEF Action

When selected, always occurs immediately

 

 

 

 

after detection of a critical event.

 

 

 

 

 

5.3.18.2Alert over LAN

LAN alerts are sent as SNMP traps in ASF formatted Platform Event Traps (PET) to a specified alert destination. The Alert over LAN feature is used to send either PET alerts or directed events to a remote system management application, regardless of the state of the host’s operating system.

LAN alerts may be sent over any of the LAN channels supported by a platform. LAN alerts can be used by PEF to send out alerts to selected destination whenever an event matches an event filter table entry. For more information on LAN alerts, see the IPMI specifications v1.5

5.3.19mBMC Sensor Support

The following tables are for the built-in and the external sensors for the platform. There is a management controller locator record as a built-in SDR besides the given below.

Revision 1.0

137

 

C78844-002

Page 137
Image 137
Intel SE7520JR2 manual MBMC Sensor Support, Alert over LAN, PEF Action Priorities, Revision 137 C78844-002