Connectors and Jumper Blocks

Intel® Server Board SE7520JR2

 

 

 

 

 

 

 

 

 

 

FMC Signal Name

FMC

 

Description

 

 

 

 

 

Pin

 

 

 

 

 

LAN_I2C_3VSB_SCL

58

LAN usage

 

 

 

 

 

 

 

 

 

 

HDD_FLT_LED_N

64

Drive Fault LED output driven when FMM detects a bad drive from the Hot

 

 

 

 

 

 

Swap controller on the Hot Swap disk Drive sub-system.

 

 

 

FMM_PS_PWR_ON_N

65

Power On Request to the system Power Supply

 

 

 

 

 

 

 

 

 

COOL_FLT_LED_N

66

Cool Fault LED output driven when FMM detects a bad Fan if SSI front panel is

 

 

 

 

 

 

detect.

 

 

 

 

 

 

 

 

 

 

FMM_CPU_VRD_EN

67

This signal is driven by the FMM to enable the CPU VRDs and allow the VRD

 

 

 

 

 

 

power good chain to complete. This signal can also be used to keep the system

 

 

 

 

 

 

in reset for an extended time, beyond what the chipset RST_BTN_N can

 

 

 

 

 

 

provide.

 

 

 

 

 

 

 

 

 

 

FMM_SCI_N

68

SCI event request. If ACPI EC is supported by FMM, this signal is used for ACPI

 

 

 

 

 

 

interrupts.

 

 

 

 

ICH_PWR_BTN_N

69

FMM pass through of Front panel power button to chipset

 

 

 

 

 

 

 

 

 

FMM_SPKR_N

72

FMM uses this to create Beep Codes on the system audible alarm. This signal is

 

 

 

 

 

 

configured as an Open Drain buffer in the FMM and must be pulled up to 3.3V

 

 

 

 

 

 

Standby on the motherboard

 

 

 

 

 

 

 

 

 

 

FP_NMI_BTN_N

73

NMI / Diagnostic interrupt from front panel. Actual NMI generated by SMBUS

 

 

 

 

 

 

command to mBMC

 

 

 

 

 

 

 

 

 

 

FP_SLP_BTN_N

74

Front panel Sleep Button input, if used

 

 

 

 

 

 

 

 

 

FP_ID_BTN_N

75

Front panel ID button, will cause the ID light to toggle

 

 

 

 

 

 

 

 

 

SYS_PWR_GD

76

Signal from the end of the baseboard VRD Power good chain. This signal

 

 

 

 

 

 

should be the last VRD power good indication generated on the baseboard.

 

 

 

 

 

 

Usually this would be the signal feeding the Chipset Power OK input. Used by

 

 

 

 

 

 

FMM in conjunction with RST_PWRGD_PS to determine if all critical VRDs

 

 

 

 

 

 

have successfully reached their nominal value.

 

 

 

 

 

 

 

 

 

CPU2_SKTOCC_N

80

Indicates that a Processor is in the application processor socket

 

 

 

 

 

 

 

 

 

CLK_32K_RTC

81

This signal is used for “Synchronized clock with system RTC”. FMM can

 

 

 

 

 

 

synchronize own RTC with system RTC. IPMI define synchronized method.

 

 

 

 

 

 

clock comes from the Chipset RTC function.

 

 

 

 

 

 

 

 

 

CPU1_SKTOCC_N

82

Indicates that a Processor is in the primary processor socket. If this socket is

 

 

 

 

 

 

detected empty and there’s an attempt to power up the system, the FMM will

 

 

 

 

 

 

output an Error Beep Code and prevent the System from turning on

 

 

 

 

 

 

 

 

 

FMM_SOUT

85

EMP/SOL Serial Data Out. This is the Serial Port data output from FMM and

 

 

 

 

 

 

should be connected to the SIN signal in the SIO3 device

 

 

 

 

 

 

 

 

 

FMM_SIN

86

EMP/SOL Serial Data In. This is the Serial Port data input into the FMM and

 

 

 

 

 

 

should be connected to the SOUT signal in the SIO3 device

 

 

 

 

 

 

 

 

 

FMM_DCD_N

87

EMP/SOL Data Carrier Detect. This is the Serial Port Data Carrier Detect input

 

 

 

 

 

 

into the FMM and should be connected to the DCD signal in the SIO3 device

 

 

 

 

 

 

 

 

 

FMM_RTS_N

88

EMP/SOL Request to Send. This is the Serial Port Request to Send output from

 

 

 

 

 

 

FMM and should be connected to the CTS (Clear to Send) signal in the SIO3

 

 

 

 

 

 

device

 

 

 

 

FMM_DTR_N

89

EMP/SOL Data Terminal Ready. This is the Serial Port Data Terminal Ready

 

 

 

 

 

 

output from FMM and should be connected to the DSR (Data Set Ready) signal

 

 

 

 

 

 

in the SIO3 device

 

 

 

 

 

 

 

 

 

 

FMM_CTS_N

90

EMP/SOL Clear to Send. This is the Serial Port Clear to Send input into the

 

 

 

 

 

 

FMM and should be connected to the RTS (Ready to Send) signal in the SIO

 

 

 

 

 

 

device

 

 

 

 

 

 

 

 

 

 

ICMB_RX

93

Inter Chassis Communication Management Bus receive data

 

 

 

 

 

 

 

 

 

ICMB_TX

94

Inter Chassis Communication Management Bus transmit data

 

 

 

 

 

 

 

 

 

ICMB_TX_EN

96

Inter Chassis Communication Management Bus transceiver enable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

186

 

 

C78844-002

Revision 1.0