Intel® Server Board SE7520JR2

Functional Architecture

BSP and starts executing from the reset vector (F000:FFF0h). A processor that does not perform the role of BSP is referred to as an application processor (AP).

The BSP is responsible for executing the BIOS power-on self-test (POST) and preparing the machine to boot the operating system. At boot time, the system is in virtual wire mode and the BSP alone is programmed to accept local interrupts (INTR driven by programmable interrupt controller (PIC) and non-maskable interrupt (NMI)).

As a part of the boot process, the BSP enables the application processor. When enabled, the AP programs its Memory Type Range Registers (MTRRs) to be identical to those of the BSP. The AP executes a halt instruction with its local interrupts disabled. If the BSP determines that an AP exists that is a lower-featured processor or that has a lower value returned by the CPUID function, the BSP switches to the lowest-featured processor in the system.

3.1.8CPU Thermal Sensors

The CPU temperature will be indirectly measured via thermal diodes. These are monitored by the LM93 sensor monitoring device. The mBMC configures the LM93 to monitor these sensors. The temperatures are available via mBMC IPMI sensors.

3.1.9Processor Thermal Control Sensor

The Intel Xeon processors generate a signal to indicate throttling due to a processor over temp condition. The mBMC implements an IPMI sensor that provides the percentage of time a processor has been throttled over the last 1.46 seconds. Baseboard management forces a thermal control condition when reliable system operation requires reduced power consumption.

3.1.10Processor Thermal Trip Shutdown

If a thermal overload condition exists (thermal trip), the processor outputs a digital signal that is monitored by the baseboard management sub-system. A thermal trip is a critical condition and indicates that the processor may become damaged if it continues to run. To help protect the processor, the management controller automatically powers off the system. In addition the System Status LED will change to Amber and the error condition will be logged to the System Event Log (SEL).

If either the Intel Management Module Professional Edition or Advanced Edition is present in the system, the Fault LED fro the affected processor will also be illuminated.

3.1.11Processor IERR

The IERR signal is asserted by the processor as the result of an internal error. The mBMC configures the LM93 device to monitor this signal. When this signal is asserted, the mBMC generates a processor IERR event.

3.2Intel® E7520 Chipset

The architecture of the Server Board SE7520JR2 is designed around the Intel E7520 chipset. The chipset consists of three components that together are responsible for providing the interface between all major sub-systems found on the baseboard, including the processor, memory, and I/O sub-systems. These components are: