Intel® Server Board SE7520JR2

Platform Management

5.3.5.2Reset Control Sources

The following table shows the reset sources and the actions taken by the system.

Table 48: System Reset Sources and Actions

Reset Source

System Reset?

mBMC Reset

Standby power comes up

No (no DC power)

Yes

 

 

 

DC power comes up

Yes

No

 

 

 

Reset button or in-target probe (ITP) reset

Yes

No

 

 

 

Warm boot (DOS ctrl-alt-del, for example)

Yes

No

 

 

 

Command to reset the system

Yes

No

 

 

 

Set Processor State command

Yes

No

 

 

 

Watchdog timer configured for reset

Yes

No

 

 

 

FRB3 failure

Yes

No

 

 

 

PEF action

Optional

No

 

 

 

5.3.5.3Control Panel System Reset

The reset button is a momentary contact button on the control panel. Its signal is routed through the control panel connector to the mBMC, which monitors and de-bounces it. The signal must be stable for at least 25 ms before a state change is recognized.

If Secure Mode is enabled or the button is forced protected, the reset button does not reset the system. A Platform Security Violation Attempt event message is instead generated.

Control Panel User Interface

When an optional Intel® Management Module is not present, the mBMC acts as the control panel controller2, processing signals from the control panel switches and LEDs.

When the flexible management connector is populated, the mBMC stops acting on the control panel reset and power button inputs. This becomes the responsibility of the Intel® Management Module.

The mBMC supports three control panel events.

Power button assertion

A low-level signal at PWBTIN indicates that the power button is being pressed. This input is bridged to the PWBTOUT output if Control Panel Lockout is disabled. The “Control Panel Power Button pressed” event is logged in the SEL.

Reset button assertion

A low-level signal at RSTIN indicates that the reset button is being pressed. This input is bridged to the RSTOUT output if Control Panel Lockout is disabled. The “Control Panel Reset Button pressed” event is logged in the SEL.

2The Intel® Local Control Panel with LCD, is not supported with on-board platform management. Either an IMM Professional Editaion or Advanced Edition must be installed to support this chassis option.