System BIOS

 

Intel® Server Board SE7520JR2

 

 

 

 

 

Feature

Options

Help Text

Description

 

Late POST Timeout

Disabled

This controls the time limit for

 

 

 

5 minutes

add-in card detection. The system

 

 

 

is reset on timeout.

 

 

 

10 minutes

 

 

 

 

 

 

 

15 minutes

 

 

 

 

20 minutes

 

 

 

 

 

 

 

 

Hard Disk OS Boot Timeout

Disabled

This controls the time limit

 

 

 

5 minutes

allowed for booting an operating

 

 

 

system from a Hard disk drive.

 

 

 

10 minutes

 

 

 

The action taken on timeout is

 

 

 

15 minutes

 

 

 

determined by the OS Watchdog

 

 

 

20 minutes

Timer policy setting.

 

 

 

 

 

 

 

PXE OS Boot Timeout

Disabled

This controls the time limit

 

 

 

5 minutes

allowed for booting an operating

 

 

 

system using PXE boot. The

 

 

 

10 minutes

 

 

 

action taken on timeout is

 

 

 

15 minutes

 

 

 

determined by OS Watchdog

 

 

 

20 minutes

Timer policy setting.

 

 

 

 

 

 

 

OS Watchdog Timer Policy

Stay On

Controls the policy upon timeout.

 

 

 

Reset

Stay on action will take no overt

 

 

 

action. Reset will force the

 

 

 

Power Off

 

 

 

system to reset. Power off will

 

 

 

 

 

 

 

 

force the system to power off.

 

 

 

 

 

 

 

Platform Event Filtering

Disabled

Disable trigger for system sensor

 

 

 

Enabled

events.

 

 

 

 

 

 

 

 

 

 

 

4.4.2.5.1System Management Sub-menu SelectionsTable 39: BIOS Setup, System Management Sub-menu Selections

 

 

 

Feature

Options

 

Help Text

Description

 

 

 

Server Board Part Number

N/A

 

N/A

Field contents varies

 

 

 

 

 

 

 

 

 

 

 

Server Board Serial Number

N/A

 

N/A

Field contents varies

 

 

 

 

 

 

 

 

 

 

 

NIC 1 MAC Address

N/A

 

N/A

Field contents varies

 

 

 

 

 

 

 

 

 

 

 

NIC 2 MAC Address

N/A

 

N/A

Field contents varies

 

 

 

 

 

 

 

 

 

 

 

System Part Number

N/A

 

N/A

Field contents varies

 

 

 

 

 

 

 

 

 

 

 

System Serial Number

N/A

 

N/A

Field contents varies

 

 

 

 

 

 

 

 

 

 

 

Chassis Part Number

N/A

 

N/A

Field contents varies

 

 

 

 

 

 

 

 

 

 

 

Chassis Serial Number

N/A

 

N/A

Field contents varies

 

 

 

 

 

 

 

 

 

 

 

BIOS Version

N/A

 

N/A

BIOS ID string (excluding the

 

 

 

 

 

 

 

 

build time and date).

 

 

 

 

 

 

 

 

 

 

 

BMC Device ID

N/A

 

N/A

Field contents varies

 

 

 

 

 

 

 

 

 

 

 

BMC Firmware Revision

N/A

 

N/A

Field contents varies

 

 

 

 

 

 

 

 

 

 

 

BMC Device Revision

N/A

 

N/A

Field contents varies

 

 

 

 

 

 

 

 

 

 

 

PIA Revision

N/A

 

N/A

Field contents varies

 

 

 

 

 

 

 

 

 

 

 

SDR Revision

N/A

 

N/A

Field contents varies

 

 

 

 

 

 

 

 

 

 

 

HSC FW Revision (HSBP)

N/A

 

N/A

Firmware revision of the Hot-

 

 

 

 

 

 

 

 

swap controller. Displays n/a if

 

 

 

 

 

 

 

 

the controller is not present.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100

 

 

C78844-002

Revision 1.0