Schumacher BT-250 Pass Green light, Pass & Recharge Green & Yellow lights, Fail Red light

Page 5

5.Pressing “ENTER” will move to the next step.

6. Press the ￿/￿ Key to input the

SET

￿

500

battery capacity of CCA:

 

 

 

SAE: 200–1200, ENC2: 180–1280, DIN: 110–770

Press “ENTER” to begin the test.

 

 

 

7.Test the battery for 5–7 seconds.

CAL

8.When the test is complete, The display shows the actual volts and the actual CCA. (Compared to the CCAselected in step 6). One of five results will be displayed:

PASS: (Green light)

The battery is good & capable of holding a charge.

xx.xx SAE PASS

PASS & RECHARGE: (Green & Yellow lights)

The battery is good but needs to be charged.

xx.xx

SAE

PASS CHAR

RECHARGE & RETEST: (Yellow & Red lights)

Battery is discharged. The battery condition cannot be accurately determined until it is fully charged. Recharge & retest the battery.

xx.xx SAE PASS TEST

FAIL: (Red light)

The battery will not hold a charge. It should be replaced immediately.

xx.xx SAE

FAIL

BAD CELL: (Red light)

The battery has at least one cell short circuit .It should be replaced immediately.

xx.xx SAE BAD

CELL

5

Image 5
Contents Send Warranty Product Repairs To Model BT-250 Digital Battery Tester For 12 Volt BatteriesTest Procedures / Operating Instructions Personal Safety Precautions Preparing to Test Battery Test BT-250 12 Volt Batteries OnlyOperation & USE IbtLPass & Recharge Green & Yellow lights Pass Green lightRecharge & Retest Yellow & Red lights Fail Red lightLoad Error Page Limited Warranty