Ingersoll-Rand 8246-D Troubleshooting, Accessories, Condition, Possiblecause, Correctiveaction

Page 11

TROUBLESHOOTING

M104

13

LISTEDBELOWARESOMEOFTHEMOSTCOMMONCAUSESFORTHESELF-FEEDDRILLTOMALFUNCTIONMALFUNCTIONS.BEYONDTHESCOPE OFTHISMANUALSHOULDBEBROUGHTTOTHEATTENTIONOFYOURAROREPRESENTATIVEORRETURNTHETOOLTOFACTORYFORREPAIR.

CONDITION

Failure to feed or irregularor erraticfeed

Low speed or motor fails to operate.

Motor continues to run after retractron

Failure to retrack

POSSIBLECAUSE

1. Inadequate air supply

2Feed control valves improp- erly adjusted.

3.Air leak around cap (12).

4.Dirt or damaged ”O”rings on spool valve (14).

5Clogged air passage in valve housing.

1.Inadequate air supply.

2.Clogged air passage in valve housing.

1.Piston not fully retracted

2.Damaged ”O”ring (11)inside valve housing.

1.Improper adjustment or align- ment between adjustment screw and button bleed valve.

CORRECTIVEACTION

1 Check air supply for correct regulator adjustment (90 p.s.i.g max. when tool is operating).

2. Referto set-up procedure, page 1.

3Check for damage to”O” ring. Check and insure caps are properly tightened.

4.Refer to valve section, page 9, and remove spool valve. Inspect, clean and replace ”O” rings.

5.Removevalve housing from tool. Disassemble and blow all air passages clear of debris.

1. Check air supply for correct regulator adjustment.

2Removevalve housing from tool. Disassemble and blow all air passages clear of debris.

1.Insure piston is not obstructed and is returned all the way back

2.Removevalve housing from tool. Replace“0” rings.

1 Referto set-up procedure, page 1

2.Feed control valves (23) improp- erly adjusted or dirty

3 Air leak around cap (12)

4.Damaged ”O” rings muffler cap valve housing or spool valve or seals on piston.

2.Check adjustment, refer to page 2. Remove, inspect and clean,

3Check for damage to“O”ring. Check and insure caps are properly tightened.

4. Disassemble,inspect and replace “O”rings and/or seals.

5. Clogged air passage in valve

5. Removevalve housing from tool. Disassembleand blow air

housing

passages clear of debris.

ACCESSORIES

11

Image 11
Contents Lubricated AIR Supply BANT-A-MATIC SELF-FEED DrillsRemoteoperation Recommendedpower AIR Inlet SystemFeedratecontrolvalves ManualoperationRemote Operation AdjustmentscrewBasic Remotecontrolforstart Emergencyretractfunctions 44800 TAPMATICATTACHMENT& Torquearm ASS’Y DISASSEMBLY/ASSEMBLYINSTRUCTIONSM104Tapperdisassembly TapperassemblyPage Ml04 Motor Valve Housingdisassembly DISASSEMBLY/ASSEMBLYINSTRUCTIONSGearingdisassembly AIR PistonassemblyQTY PARTNO. Description QTY PARTNO. Description Service KIT noPossiblecause TroubleshootingAccessories ConditionDimensionaldata