Ingersoll-Rand FE074B( )A( ) specifications Series 7 ELECTRA-FEED Drill, Recommended Lubricants

Page 1

 

OPERATOR’S MANUAL

SECTION

M107

R

MANUAL

26

 

 

 

INCLUDING:"OPERATION,"INSTALLATION"&"MAINTENANCE

Released: 5-15-98

 

 

SERIES 7 ELECTRA–FEED DRILL

Revised: 11-20-99

 

 

49999-543

 

Models FE074B–( )–A( )

READ THIS MANUAL CAREFULLY BEFORE INSTALLING,

OPERATING OR SERVICING THIS EQUIPMENT.

It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference.

OPERATING AND SAFETY PRECAUTIONS

Keep hands and clothing away from rotating end of tool and all moving parts of the tool.

Wear suitable eye protection while operating tool or when near tool when it is being operated.

Disconnect air and electrical supply from tool before remov- ing/installing bits or performing other maintenance or service procedures.

ROUTINE LUBRICATION REQUIREMENTS

When this tool was built, an “O” ring lubricant was applied to all ap- propriate dynamic seals to insure continued operation. Drive train components and bearings were also supplied / filled with grease to insure appropriate life of components. As long as all exterior seals and wipers are maintained in good working order and all covers and breather vents are kept in place, it is reasonable to ex- pect that external debris will not enter the tool. It is also reason- able to expect that lubricants applied to the tool interior will require replenishment for at least 5000 hours of normal operation. Adding spindle oil to the power air inlet of this tool is not necessary.

MOUNTING

AIR SUPPLY REQUIREMENTS

For maximum operating efficiency, the following air supply specifi- cations should be maintained to this air tool:

AIR PRESSURE – 90 PSIG (6 bar)

AIR FILTRATION – 50 micron

HOSE SIZE – 5/16” (8 mm) I.D.

An AROR model P29231–110 air line FILTER/REGULATOR plus 100067 gauge is recommended to maintain the above air supply specifications.

RECOMMENDED LUBRICANTS

After disassembly is complete, all parts, except sealed or shielded bearings, should be washed with solvent. To relubricate parts, or for routine lubrication, use the following recommended lubricants:

Where Used

ARO Part #

Description

‘‘O” Rings, Lip Seals

36460

4 oz. Stringy Lubricant

and Air Cylinder

 

 

Sliding Splines and

33153

5 lb. ‘‘EP” – NLGI #1

Bearings

 

Grease

Mounting clamps 49690 and 46982–1are available for mounting of this tool. These items are shown on page 11. Both mounts allow the clamp to grip the outer sleeve of the tool and feature keyways for alignment.

For parts and service information, contact your local ARO distributor, or the Customer Service Dept. of the Ingersoll–Rand Distribution Center, White House, TN at PH: (615) 672–0321, FAX: (615) 672–0801.

ARO Tool Products

Ingersoll–Rand Company

1725 U.S. No. 1 North D P.O. Box 8000 D Southern Pines, NC 28388–8000

E1999 INGERSOLL–RAND COMPANY D PRINTED IN U.S.A.

Image 1
Contents Series 7 ELECTRA-FEED Drill Operating and Safety PrecautionsRoutine Lubrication Requirements Mounting AIR Supply RequirementsModel Identification InstallationDISASSEMBLY/ASSEMBLY Instructions Piston Section Disassembly Pulley Spindle Section AssemblyPiston Section Assembly Valve Housing Section DisassemblyM107 45 43 44 L47 49 Q 40 Q 67 Q 73 s 37 Q 6936 26 Q 24 Q 61 Q Included in 49594 Service KIT Manifold Disassembly Manifold Assembly Manifold AssemblyControl Disassembly Control AssemblyTo Control Breakthrough Hydraulic Check SET-UPClamp Assembly AccessoriesMount Assembly Cross Section