connected to the same circuit, the total electrica! load must be considered in selecting the proper wire size DO NOT USE UNDERSIZE WIRE
FUSES., Refer to the National Electric Code to determine the proper fuse or circuit breaker rating required. When selecting fuses, remember the momentary starting current of an electric motor is greater than its full load current
T = Supply Line Terminal
L = Load Terminal
uJ L=J
L1
Pressure switch
used disconnecLor clrcu_breakert
(inctltde_
Singie phase m_or
COMPRESSOR LUBRICATION
CAUTION Do not operate without lubricant or with inadequate lubricant.
compressor failure caused by inadequate lubrication
SYNTHETIC LUBRICANT. We recommend
ALTERNATE LUBRfOANTS. You may use a
contains only
See the petroleum lubricant viscosity table below The table is intended as a general guide only Heavy duty operating conditions require heavier viscosities,, Refer specific operating conditions to _our dealer for recommendations
Temperature | Around Unit | Vlscosib' @ 100"F (37 8"C) | Viscosity | Grade | ||
_F |
| "C | SUS | Centtstokes | 1SO | SAE |
40 & below | 4 4 | & below | 150 | 32 | 32 | 10 |
40 - BO | 4 | 4 - 26 7 | 500 | t10 | !00 | 30 |
80 - 125 | 26.7 - 51.0 | 750 | 165 | '_50 | 40 |
you use a
decide to convert to
later on, the compressor valves must be thoroughly decarbonized
and the crankcase must be flushed before conversion
FILLING PROCEDURES:
t,, Unscrew and remove the ell fill plug (A)
2.Slowly flit the crankcase with lubricant until the lubricant reaches the top thread of the sit filI opening and the top of the sight glass Crankcase capacity for the SS3 Is
3.Replace the oil fill plug HAND TIGHT ONLY
Filling Procedures
INITIAL START-UP
Follow this procedure before putting the unit into service for the first time:
t.Set the pressure swffch lever to "OFF"..
Pressure Switch Lever
OFF"ON/AUTO
2.Open the service valve fully to prevent air pressure from building in the tank. (A=Open, B=Closed)
Service Valve
3.Move the pressure switch lever to "ON/AUTO _ The unit will start
4.Run the unit for 30 minutes Ensure the service vaive is fully open and there is no tank pressure build up
CAUTION Unusual noise or vibration indicates a problem Do not continue to operate until you identify and
correct the source of the problem., IF EMERGENCY CONDITIONS ARE ENCOUNTERED, SHUT OFF THE MAIN POWER IMMEDIATELY,
5., After 30 minutes, close the service valve fully. The air receiver will fill
to
use
B[o]"J=1:_.,_II[=]h
GENERAL
Your air compressor was designed for f 00% continuous duty operation with the use of