Extension Cords

1.Grounded tools require a three wire extension cord. Double Insulated tools can use either a two or three wire extension cord.

2.As the distance from the supply outlet increases, you must use a heavier gauge extension cord. Using exten- sion cords with inadequately sized wire causes a serious drop in voltage, result- ing in loss of power and possible tool damage. (See Table A.)

3.The smaller the gauge number of the wire, the greater the capacity of the cord. For example, a 14 gauge cord can carry a higher current than a 16 gauge cord. (See Table A.)

4.When using more than one exten- sion cord to make up the total length, make sure each cord contains at least the minimum wire size required. (See

Table A.)

5.If you are using one extension cord for more than one tool, add the nameplate amperes and use the sum to determine the required minimum cord size. (See

Table A.)

6.If you are using an extension cord out- doors, make sure it is marked with the suffix “W-A” (“W” in Canada) to indicate it is acceptable for outdoor use.

7.Make sure the extension cord is proper- ly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified electrician before using it.

8.Protect the extension cords from sharp objects, excessive heat, and damp or wet areas.

RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*

(120/240 VOLT)

NAMEPLATE

EXTENSION CORD

 

LENGTH

 

AMPERES

 

 

25’

50’

75’

100’

150’

(at full load)

 

 

 

 

 

 

 

 

 

 

 

0 – 2.0

18

18

18

18

16

2.1

– 3.4

18

18

18

16

14

3.5

– 5.0

18

18

16

14

12

5.1

– 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1

– 16.0

14

12

10

-

-

16.1

– 20.0

12

10

-

-

-

*Based on limiting the line TABLE A voltage drop to five volts at

150% of the rated amperes.

Symbology

 

 

 

Double Insulated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Canadian Standards

 

 

 

Association

 

 

 

Underwriters Laboratories, Inc.

 

 

 

 

V~

Volts Alternating Current

 

A

Amperes

 

 

 

 

 

 

 

n0 xxxx/min.

No Load Revolutions per

Minute (RPM)

SKU 95065

For technical questions, please call 1-800-444-3353

Page

Image 6
Contents Volt Rechargeable Cordless Screwdriver Electrical Safety SpecificationsGeneral Safety Rules Save This ManualPersonal Safety Tool Use and CareSpecific Safety Rules For this Product ServiceVibration Hazard Grounding Grounded Tools Tools with Three Prong PlugsDouble Insulated Tools Tools with Two Prong Plugs Symbology Extension CordsBattery Precautions UnpackingCharging the Battery Testing the Battery ChargeOperating instructions Troubleshooting MaintenanceParts List Assembly DrawingLimited 90 DAY Warranty