Extension Cords

1.Grounded tools require a three wire extension cord. Double Insulated tools can use either a two or three wire extension cord.

2.As the distance from the supply outlet increases, you must use a heavier gauge extension cord. Using extension cords with inadequately sized wire causes a serious drop in voltage, resulting in loss of power and possible tool damage.

(See Table A.)

3.The smaller the gauge number of the wire, the greater the capacity of the cord. For example, a 14 gauge cord can carry a higher current than a 16 gauge cord.

(See Table A.)

4.When using more than one extension cord to make up the total length, make sure each cord contains at least the minimum wire size required.

(See Table A.)

5.If you are using one extension cord for more than one tool, add the nameplate amperes and use the sum to determine the required minimum cord size.

(See Table A.)

6.If you are using an extension cord outdoors, make sure it is marked with the suffix “W-A” (“W” in Canada) to indicate it is acceptable for outdoor use.

7.Make sure the extension cord is properly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified electrician before using it.

8.Protect the extension cords from sharp objects, excessive heat, and damp or wet areas.

RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS* (120/240 VOLT)

NAMEPLATE

EXTENSION CORD

AMPERES

 

LENGTH

 

(at full load)

25’

50’

75’

100’

150’

0 – 2.0

18

18

18

18

16

2.1

– 3.4

18

18

18

16

14

3.5

– 5.0

18

18

16

14

12

5.1

– 7.0

18

16

14

12

12

7.1 – 12.0

18

14

12

10

-

12.1

– 16.0

14

12

10

-

-

16.1

– 20.0

12

10

-

-

-

TABLE A

* Based on limiting the line volt-

age drop to five volts at 150% of

the rated amperes.

 

 

 

 

Symbology

 

 

 

Double Insulated

 

 

 

Canadian Standards Association

 

 

 

Underwriters Laboratories, Inc.

 

 

V~

Volts Alternating Current

A

Amperes

 

 

 

n0 xxxx/min.

No Load Revolutions per Minute

(RPM)

SKU 9624

For technical questions, please call 1-800-444-3353.

Page 7

Image 7
Contents Electric Drywall Screwdriver For technical questions or replacement parts, please callSave This Manual General Power Tool Safety WarningsSave all warnings and instructions for future reference Any power tool that cannot be controlled Screwdriver and Impact Wrench Safety Warnings Vibration Safety Prong Plug and Outlet GroundingOutlet See 3-Prong Plug and OutletSee Table a Extension Cords25’ 50’ 75’ 100’ 150’ To Change Bit Tip Holders SpecificationsAssembly Instructions UnpackingSKU For technical questions, please call Operating InstructionsTo Change The Bit See Figure BPlease Read Following Carefully INSPECTION, Maintenance CleaningDo not use damaged equipment Part Description Parts List and DiagramRecord Product’s Serial Number Here Limited 90 DAY Warranty