SETUP

Using the Depth Stop

If a kerfing or rabbet cut which does not cut through the workpiece is desired, use the Depth Stop Bolt to control the depth of the cut.

WARNING! Only adjust the front Bolt. The rear Bolt is used to prevent the Blade from cutting the table during normal cutting. Do not adjust the rear Depth Bolt.

1.

Unlock the Head Lock-down, see page 9.

 

Depth Stop

2.

Raise the saw head assembly.

 

Bolt (136)

 

 

3.

Push the Depth Stop to the left to

 

Depth Stop

 

use the Depth Stop Bolt setting.

 

Nut (137)

4.

Pull down on the saw head to

 

 

 

check the current setting.

 

 

5.

To change the setting, first loosen the knurled

 

Depth

 

Depth Stop Nut on the Depth Stop Bolt.

Figure D

 

Stop (44)

 

Turn the Depth Stop Bolt clockwise to decrease

 

 

 

depth and counterclockwise to increase depth. Tighten the Depth Stop Nut after adjustment.

6.If needed, push the Depth Stop to the right to temporarily disable it.

Workpiece and Work Area Set Up

OPERATION

MAINTENANCE

1.Designate a work area that is clean and well‑lit. The work area must not allow access by children or pets to prevent injury and distraction.

2.Route the power cord along a safe route to reach the work area without creating a tripping hazard or exposing the power cord to possible damage. The power cord must reach the work area with enough extra length to allow free movement while working.

3.Allow room on both left and right of saw for extended workpieces.

4.Use a saw table, saw stand or other means to support the workpiece. Mount the Miter Saw so that the surface is level to the ground, and additional supports provide a surface on the same level as the saw table. If the work surface and any workpiece supports are not level, and on the same level, unwanted bevel angles will appear in the cuts resulting in poor joinery.

5.Secure workpieces to the saw table using the Clamp or other clamping devices (not included). Securing the workpiece will provide safety by preventing kick back and by removing the need to hold workpieces near the blade by hand. Clamping the workpiece will also improve cutting accuracy by preventing the workpiece from moving during the cutting operation.

Page 12

For technical questions, please call 1-800-444-3353.

Item 69684

Image 12
Contents Miter SAW Table of Contents General Tool Safety Warnings Miter Saw Safety Warnings Grounding InstructionsOutlets for 2-Prong Plug See Outlets for 2-Prong PlugVibration Safety Specifications 216045Assembly Setup Before UseMounting Functions Lock Trigger Lower Guard Blade Clamp TurntableMiter Description of Selected Functions Head Lock-downReplacing the Blade Operating InstructionsUsing the Workpiece Extension Supports Adjusting the Miter AngleAdjusting the Bevel Angle Bevel IndicatorUsing the Depth Stop Workpiece and Work Area Set UpGeneral Operating Instructions Cleaning, Maintenance, and Lubrication Maintenance and ServicingIf Fence needs adjustment Checking and Calibrating the FenceCalibrating the Miter Table Indicator Adjusting or Replacing the Kerf BoardTo adjust the Kerf Board Calibrating the Bevel AngleTroubleshooting Problem Possible Causes Likely SolutionsParts List Parts List and DiagramRecord Product’s Serial Number Here 111 Assembly Diagram Limited 90 Day Warranty Mission Oaks Blvd. PO Box 6009 Camarillo, CA 93011 800

69684 specifications

The Chicago Electric 69684 is a portable generator renowned for its reliable performance and essential features tailored for both home and outdoor use. This generator is particularly popular among DIY enthusiasts, campers, and homeowners looking for a dependable backup power solution during outages.

One of the standout features of the Chicago Electric 69684 is its robust 8750 watts peak output and 7000 watts running output, which provide ample power for various electrical devices. This makes it suitable for powering essential home appliances, tools, and recreational equipment. The generator is equipped with a 420cc OHV engine that promises durability and fuel efficiency, ensuring it operates effectively under demanding conditions.

The design of the Chicago Electric 69684 emphasizes user-friendliness and portability. Weighing approximately 150 pounds, it comes with built-in wheels and a foldable handle, enabling easy transport and maneuverability, whether you are moving it around the home or taking it on outdoor adventures. Its compact size allows for easy storage in garages or sheds without taking up too much space.

The generator features a durable steel frame that enhances its longevity and withstands rugged environments. Moreover, its low oil shutdown technology protects the engine, ensuring longevity and minimizing maintenance efforts. This feature automatically turns off the generator when oil levels are too low, preventing damage and encouraging responsible fuel management.

Users will appreciate the multiple outlets available on the Chicago Electric 69684. It includes standard 120V household outlets as well as 120/240V twist-lock outlets, making it versatile for various applications. The inclusion of a circuit breaker also helps protect connected devices from overloading, adding an extra layer of safety.

The noise level of the Chicago Electric 69684 is comparable to that of other generators in its class, making it a practical choice for residential areas. Although it generates a significant amount of power, it operates at a relatively low decibel level, allowing users to enjoy a quieter environment during usage.

Additionally, the generator is designed with fuel efficiency in mind, allowing for extended run times on a single tank. This feature is particularly advantageous for users who require consistent power without frequent refueling interruptions.

In conclusion, the Chicago Electric 69684 portable generator stands out with its powerful performance, user-friendly design, and safety features, making it a valuable addition for anyone in need of reliable backup power or outdoor electrical supply. Its blend of durability, efficiency, and portability ensures that it meets a wide range of power needs effectively.