Husqvarna DS160C manuel dutilisation Operation Positions, Fastening the Drill Stand Base Plate

Page 10

11. Operation Positions

The drill stand can be used for drilling ceilings, floors and walls. Individual safety instructions for each area of applications as described in the following chapters must be observed and complied with.

The three main drilling directions (area of application) are:

Floor position:

The feed direction is vertical and downward.

Wall position:

The feed direction is horizontal.

Overhead position:The feed direction is vertical and upwards.

Floor Positions

A falling core can cause serious injury. The danger zone underneath the drilling area must be sealed off and the core must be supported.

Wall Position

Before drilling into a wall, the operator must ensure that there are no obstructions at the exit point and that there is no risk of injury.

Overhead Drilling

It is not permitted to secure the drill by means of the vacuum plate when carrying out overhead drilling. Follow local codes for anchoring overhead. Overhead drilling may only be carried out if a water collector and vacuum collection system is used. During overhead drilling, only use impact anchors suitable for zones subject to tensile force.

Angle Drilling

When angle drilling, always work at low drilling pressure until the drill bit is completely engaged.

12. Fastening the Drill Stand (Base Plate)

There are three options available for fastening the base plate;

Fastening with threaded rod and heavy-duty anchor or impact anchor;

Fastening by means of a threaded rod and locking nut with washer;

Fastening by means of a vacuum plate and vacuum pump.

Fastening by means of a Threaded Rod and Heavy-Duty Anchor or Impact Anchor

Fastening the drill stand base plate should be carried out without the drill motor installed.

To ensure that the device is securely fastened, only use heavy-duty anchors or impact anchors approved by the building inspection authorities which may vary by country, providence, county or city. When working overhead, only use anchors suitable for zones subject to tensile force. For details of minimum tensile force, see, “Technical Specifications”.

10

Image 10
Contents DS160C Page ·REFER to MANUAL· Usage to the Intended Purpose Improper UsageGeneral Safety Instructions Technical Specifications MotorsHandling Transport AssemblyDescription and Features of the Drill Stand Inspection Before Starting UpElectrical Connection Fitting and Removing the MotorMounting Methods Designation of the Components Operation Positions Fastening the Drill Stand Base PlateFastening by means of a Thread Rod, Washer and Lock Nut Fastening by means of a Vacuum PlateMounting the Drill Carriage Setting the Angle of the ColumnOperating the Feed Routine Checks MaintenanceAdjusting Carriage Rollers Following routine checks should be carried out monthlySpare Parts Stocking Spare Parts Side Cleaning PlatesWear Cylinders Ordering Spare Parts24 25 26 Part Number Qty Drill Stand PartsDescription CommentsPage 541404784 Item 1 2 3 4 5 6 7 8 9 10 Description Part Number Qty Comments Item 1 2 3 4 5 Description Part Number Qty Comments Product Limited Warranty Original consumer purchaser
Related manuals
Manual 24 pages 50 Kb