11. TROUBLESHOOTING

Should trouble occur, first check connector connections.

PROBLEMS

CAUSE

COUNTERMEASURES

 

 

 

With Main SW

Power is not supplied.

Plug in correctly

ON, no activation

 

 

 

Power supply/voltage is not correct.

Make sure that power supply/voltage is

 

 

correct

 

 

 

Irregular sound

Greasing to gear mesh portion is not

Apply greasing or eliminate extraneous

emitted from

satisfactory, or extraneous matter

matter.

inside Cabinet

mixed in.

 

 

 

 

The color of the

Connector connections are defective.

Check the connection for the RGB and

image on PROJ.

 

SYNC connectors of the PROJ. TERM.

screen is incorrect.

 

BD and VPM BUFFER BD.

 

 

 

The image on PROJ.

Affected by the magnetic field of

Make CONVERGENCE adjustment.

screen has color

installation location.

(Refer to Section 12.)

deviation.

 

 

 

 

 

No sound is emitted.

Sound Volume adjustment is not

Adjust sound volume. (see Section 7).

 

appropriate.

 

 

Sound BD and speaker are

Perform sound test to find and replace

 

malfunctioning.

defective parts.(Refer to Section 7).

 

 

 

*NETWORK check

Communication cable’s connection

Perform V.R. setting, Adjustment.

will not finish.

failure.

 

 

 

 

*Communication play

Communication cable’s connection

Check for Communication cable

is not possible.

failure.

disconnection

 

Communication Play setting is wrong.

Correctly set in test mode.

 

 

 

29

Image 32
Contents 1ST Printing March Warranty Table of Contents Sega ENTERPRISES, INC. USA General Precautions Listed Precautions to be Heeded for Operation Precautions to be Heeded During OperationWhen Assembled Name of PartsAccessories Filter BoardAssembling and Installation Assy of CabinetSecuring in Place Adjuster Adjustment Power Supply Assycheck VengeCRT Test Precations to be Heeded When Moving the Machine Explanation of Test and Data Display Items DescriptionSwitch Unit and Coin Meter Sound VolumeService Button Service SW Switch UnitCoin Chute Type Input Test Selection of Desired Item Violence ModeExit Select with Service Button Press Test Button to Exit Stick Setting Adjusting the Volume ValueBookkeeping Back UP Data Clear 2/2 displays by-play-time play frequencyCoin Selector Coin Meter Gate CradleOptional Dollar Bill Acceptor Page Monitor Primary side and secondary sidePage Page Replacement of Fluorescent Lamp Replacement of Fluorescent LampPower Supply Plug Cleaning Cabinet SurfacesPeriodic Inspection Table Coin Chute TowerTroubleshooting Problems Cause CountermeasuresNaomi Game BD Game Board12 -1 Removing the Game Board Assy Case NAO USA 840-0003D-01 Zombie USA DIP SW Settings 12 -2 Composition of Game BoardDesign Related Parts Parts List TOP Assy ZBXAC Unit Assy Monitor 29TYPE 31KSee Description Assy Control Panel ZBX Assy SUB Cabi ZBX LEG Adjuster Bolt M16X75 Not Available Assy SUB-CABINET ZBXAIR Vent See Description Assy Elec BaseLocal Purchase FL Ballast 20W FL Bulb 20W Assy BillboardMarquee Plex Assy Control Panel Control Panel Plate ZBX NAOPB SW W/L 6V 1L Y Assy Analog JOY 4C GreenSW Unit TNG LKGBOX-CASH Cash BOX Hole CoverSwitch Brkt Assy SW Unit SPG5-0350SW PB 1M VOL Cont B-5K OHMAssy AC Unit DRT1-0400 AC BrktBushing Strain Relief 6N34 Local Purchase Fuse 5AAssy Monitor 29TYPE 31K HOD1-1570 Monitor Brkt aMonitor Brkt B Bush for TVAudio Power AMP 2CH Not Available Wooden Base ElecLocal Purchase Fuse Block W/ Fuses PWR SpplyROM Case NAO Assy Shield Case NAO ZBX 840-0003D-01Shield Case ZBX NAO USA Come see Sega ENTERPRISES’ Service Department Homepage