Sterling Plumbing 150, 225, 90, 100, Cabinet Series Dehumidifying Dryer installation manual Pid

Page 47

Level 2

Cn5L input shift lower limit

 

-999.9 to 999.9°C

0.0

Default

 

 

 

 

 

Mode

Parameter

Setting range

Default

Factory

 

 

 

 

 

 

setting

Setup

Cn-t Input Type

0 to 21

2

17

Setup

Cn-H Scaling Upper Limit

Scaling Lower Limit +1 to

-100

15°F/-9C

9999 EU

 

 

 

 

 

 

Setup

Cn-L Scaling Lower Limit

-1999 to SP Setting Upper

0

-40°F/-40C

Limit –0.1 EU

 

 

 

 

 

 

Setup

dP Decimal Point

0 to 3

0

Default

Setup

CnCE Parameter Initialize

Yes/No

No

Default

Setup

6Ut1 Control Output 1

Heat/Cool/Alarm 1/Alarm 2/

Heat

COOL

Assignment

Alarm 3/LBA

 

 

 

 

Setup

6Ut2 Control Output 2

Heat/Cool/Alarm 1/Alarm 2/

AL-1

Default

Assignment

Alarm 3/LBA

 

 

 

 

SetUp

Sub 1 Auxiliary Output 1

Alarm 1/Alm 2/Alm 3/LBA/S.

AL-2

Default

Assignment

ERR/E333

 

 

 

 

Setup

ALt1 Alarm 1 Type

0 to 11

2

8

Setup

AL1n Alarm 1 open in alarm

NO/NC

NO

Default

Setup

ALt2 Alarm 2 Type

0 to 11

2

8

Setup

AL2n Alarm 2 open in alarm

NO/NC

NO

Default

Setup

6rEU Direct/Reverse

OR-R/OR-D

OR-R

Default

Operation

 

 

 

 

 

Expansion

SL-H Set Point Upper Limit

SP Lower Limit +1 to

1300

15°F/-9C

Scaling Upper Limit

 

 

 

 

 

 

Expansion

SL-L Set Point Lower Limit

Scaling Upper Limit to Sp

-200

-40°F/-40C

Lower Limit

 

 

 

 

 

 

Expansion

CntL PID/ON/OFF

PID/ON-OFF

PID

ON-OFF

Expansion

rESt Standby Sequence

0/1

0

Default

 

 

Reset Setting Method

 

 

 

Expansion

rEt Automatic Return of

0 to 99 SEC

0

Default

 

 

Display Mode

 

 

 

6-8 Restoring the E5CK Temperature Controller and Dew Point Meter to Factory Setup

If preset parameters on the controller have been tampered with and it no longer properly controls temperature and displays dew point, you can restore the controller to factory setup.

Cabinet Series Dehumidifying Dryer

47

Image 47
Contents 90,100, 150, 225 CFM Cabinet Series Dehumidifying Dryers Bulletin No. DH1-630.1 Table of Contents TROUBLESHOOTING…………………………….48 Charts and Figures Safety Symbols Used in this Manual SafetyHow to Use This Manual Description Operator Responsibility ResponsibilityGeneral Responsibility Maintenance Responsibility Reporting a Safety Defect General Information Closed Loop Drying System Dryer Air Flow DiagramSpecifying a Drying/Conveying System What is Desiccant?Process/Regeneration Cycle Making Electrical Connections InstallationConnecting Compressed Air Positioning Your DryerDrying Hopper Connecting Cooling Water to the Optional AftercoolerProcess Air Connections Between the Dryer and Drying Hopper Indicating Lights Control Panel Indicator Lights and SwitchesRocker Switches ControlsSignal to the PLC controller to shut down dryer Typical Dyer Interface Panel Process Air Dew Point Display Process Air Temperature ControllerIdentifying Temperature Controller LED Indicators Auto-Tune Button Identifying Temperature Controller Buttons Display ButtonDown Arrow Button Up Arrow ButtonAvailable E5CK Modes E5CK Operating ParametersPLC Controller Setting the Process Air TemperatureName Description PLC LED IndicatorsOutput LED Indicators Typical Subpanel Layout Typical Cabinet Dryer Electrical Schematic, Drawing Typical Cabinet Dryer Electrical Schematic, Drawing 222 Entering Operating Parameters to Select Modes Setting the Shift on Dew PointSetting the High Dew Point Alarm Display Optional Seven Day TimerTimer Setting the Current Day of the Week, Hour, and Minute Programming the Optional TimerMultiple-Day Operation Daily Timer OperationChecking the Set Time Day Override Canceling the SettingsCabinet Series Dehumidifying Dryer Shutdown OperationPre-Startup Checks StartupPage Servicing Process Air Filters MaintenanceWork Rules Washing Recommendations for Cleaning and Replacing FiltersCleaning with Compressed Air VacuumingEvery two years Preventative Maintenance ChecklistSystem model # Serial # Jan Feb Mar Apr May Jun Jul Aug Sep Oct NovServicing the Dew Point Monitor Symptoms of Worn DesiccantFirst Aid Replacing Worn DesiccantLbs Replacing the Process HeaterDryer Large bead Type Small bead Type Total per bed Changing the Controller Security Level Mode Security levelReplacing the Regeneration Heater Mode Parameter Setting range Default Factory Setting Mode Parameter Setting rangeOption Boards Parameter Setting rangeOption Type RE232C RS-485 Event Input Transfer Output Restoring Factory Defaults on the Dew Point ControllerPID Cabinet Series Dehumidifying Dryer Stop the dryer TroubleshootingProblem Possible cause Corrective action PLC Using a Platinum Resistance Thermometer Determining Temperature Controller Errors or Sensor ErrorsUsing a Thermocouple Parts Department Technical SpecificationsService Department Contact Information

100, 150, 90, Cabinet Series Dehumidifying Dryer, 225 specifications

The Sterling Plumbing 150, 225, 90 Cabinet Series Dehumidifying Dryer is a state-of-the-art appliance designed to effectively eliminate excess moisture in various environments. This versatile dryer is ideal for residential, commercial, and industrial applications, providing reliable moisture control to enhance air quality and prevent damage due to humidity.

One of the main features of the Sterling Plumbing Dehumidifying Dryer is its impressive moisture removal capacity. With options available for 150, 225, and 90 pint per day configurations, this unit can cater to different sizes and types of spaces, making it a suitable choice for everything from small basements to large warehouses. Its cabinet design allows for efficient air circulation, maximizing its dehumidification capabilities while remaining compact and easy to install.

The technology integrated within the Sterling Plumbing Dehumidifying Dryer is advanced, incorporating a high-efficiency compressor and a durable, corrosion-resistant housing. This ensures that the unit operates quietly and efficiently, providing a long service life with minimal maintenance required. The dryer features an automatic humidistat that monitors the humidity levels in the environment, adjusting its operation to maintain desired settings without manual intervention. This smart technology not only conserves energy but also ensures optimal performance.

In addition to its dehumidification function, the Sterling dryer is equipped with a built-in air filtration system that captures dust and allergens, contributing to overall indoor air quality. The easy-to-clean filters are designed for durability, ensuring that the unit remains functional and effective over time.

Another notable characteristic of the Sterling Plumbing Dehumidifying Dryer is its user-friendly interface. The control panel is designed to be intuitive, allowing users to easily set their preferred humidity levels and adjust operation modes. With options for continuous drainage, users can also opt to run the unit without worrying about emptying the water tank frequently.

Overall, the Sterling Plumbing 150, 225, 90 Cabinet Series Dehumidifying Dryer is a powerful, efficient, and reliable moisture management solution. With its blend of advanced technology, user-friendly features, and robust design, it is an essential appliance for anyone looking to improve indoor air quality and protect their space from the damaging effects of excess moisture.