Sterling Plumbing 150, 225, 90, 100, Cabinet Series Dehumidifying Dryer Description

Page 7

Dryer Safety Tags

Tag

 

Description

Tag

Description

 

 

 

 

 

 

 

Read Operation

 

High Voltage Inside

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

& Installation

 

 

 

 

 

 

 

 

 

Enclosure

 

 

 

 

 

 

 

Manual

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot!

 

Lifting Point

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Protected Earth

 

 

 

 

PE

 

 

 

Earth Ground

 

 

 

Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-2 Warnings and Precautions

Our equipment is designed to provide safe and reliable operation when installed and operated within design specifications, following national and local safety codes. This may include, but is not limited to OSHA, NEC, CSA, SPI, and any other local, national and international regulations.

To avoid possible personal injury or equipment damage when installing, operating, or maintaining this equipment, use good judgment and follow these safe practices:

;Read and follow these operation and installation instructions when installing, operating, and maintaining this equipment. If these instructions become damaged or unreadable, additional copies are available from the manufacturer.

;Follow all SAFETY CODES.

;Wear SAFETY GLASSES and WORK GLOVES.

;Work only with approved tools and devices.

;Disconnect and/or lock out power before servicing or maintaining the equipment.

;Use care when LOADING, UNLOADING, RIGGING, or MOVING this equipment.

;Operate this equipment within design specifications.

;OPEN, TAG, and LOCK ALL DISCONNECTS before working on equipment. You should remove the fuses and carry them with you.

;Make sure the equipment and components are properly GROUNDED before you switch on power.

;When welding or brazing in or around this equipment, make sure VENTILATION is ADEQUATE. PROTECT adjacent materials from flame or sparks by shielding with sheet metal. An approved FIRE EXTINGUISHER should be nearby and ready for use if needed.

;Do not restore power until you remove all tools, test equipment, etc., and the equipment and related components are fully reassembled.

;Only PROPERLY TRAINED personnel familiar with the information in this manual should work on this equipment.

Cabinet Series Dehumidifying Dryer

7

Image 7
Contents 90,100, 150, 225 CFM Cabinet Series Dehumidifying Dryers Bulletin No. DH1-630.1 Table of Contents TROUBLESHOOTING…………………………….48 Charts and Figures How to Use This Manual SafetySafety Symbols Used in this Manual Description General Responsibility ResponsibilityOperator Responsibility Maintenance Responsibility Reporting a Safety Defect General Information Closed Loop Drying System Dryer Air Flow DiagramProcess/Regeneration Cycle What is Desiccant?Specifying a Drying/Conveying System Making Electrical Connections InstallationConnecting Compressed Air Positioning Your DryerProcess Air Connections Between the Dryer and Drying Hopper Connecting Cooling Water to the Optional AftercoolerDrying Hopper Indicating Lights Control Panel Indicator Lights and SwitchesRocker Switches ControlsSignal to the PLC controller to shut down dryer Typical Dyer Interface Panel Identifying Temperature Controller LED Indicators Process Air Temperature ControllerProcess Air Dew Point Display Auto-Tune Button Identifying Temperature Controller Buttons Display ButtonDown Arrow Button Up Arrow ButtonAvailable E5CK Modes E5CK Operating ParametersPLC Controller Setting the Process Air TemperatureName Description PLC LED IndicatorsOutput LED Indicators Typical Subpanel Layout Typical Cabinet Dryer Electrical Schematic, Drawing Typical Cabinet Dryer Electrical Schematic, Drawing 222 Setting the High Dew Point Alarm Setting the Shift on Dew PointEntering Operating Parameters to Select Modes Timer Optional Seven Day TimerDisplay Setting the Current Day of the Week, Hour, and Minute Programming the Optional TimerChecking the Set Time Daily Timer OperationMultiple-Day Operation Day Override Canceling the SettingsCabinet Series Dehumidifying Dryer Shutdown OperationPre-Startup Checks StartupPage Work Rules MaintenanceServicing Process Air Filters Washing Recommendations for Cleaning and Replacing FiltersCleaning with Compressed Air VacuumingEvery two years Preventative Maintenance ChecklistSystem model # Serial # Jan Feb Mar Apr May Jun Jul Aug Sep Oct NovServicing the Dew Point Monitor Symptoms of Worn DesiccantFirst Aid Replacing Worn DesiccantDryer Large bead Type Small bead Type Total per bed Replacing the Process HeaterLbs Replacing the Regeneration Heater Mode Security levelChanging the Controller Security Level Mode Parameter Setting range Default Factory Setting Mode Parameter Setting rangeOption Boards Parameter Setting rangeOption Type RE232C RS-485 Event Input Transfer Output Restoring Factory Defaults on the Dew Point ControllerPID Cabinet Series Dehumidifying Dryer Problem Possible cause Corrective action TroubleshootingStop the dryer PLC Using a Thermocouple Determining Temperature Controller Errors or Sensor ErrorsUsing a Platinum Resistance Thermometer Parts Department Technical SpecificationsService Department Contact Information

100, 150, 90, Cabinet Series Dehumidifying Dryer, 225 specifications

The Sterling Plumbing 150, 225, 90 Cabinet Series Dehumidifying Dryer is a state-of-the-art appliance designed to effectively eliminate excess moisture in various environments. This versatile dryer is ideal for residential, commercial, and industrial applications, providing reliable moisture control to enhance air quality and prevent damage due to humidity.

One of the main features of the Sterling Plumbing Dehumidifying Dryer is its impressive moisture removal capacity. With options available for 150, 225, and 90 pint per day configurations, this unit can cater to different sizes and types of spaces, making it a suitable choice for everything from small basements to large warehouses. Its cabinet design allows for efficient air circulation, maximizing its dehumidification capabilities while remaining compact and easy to install.

The technology integrated within the Sterling Plumbing Dehumidifying Dryer is advanced, incorporating a high-efficiency compressor and a durable, corrosion-resistant housing. This ensures that the unit operates quietly and efficiently, providing a long service life with minimal maintenance required. The dryer features an automatic humidistat that monitors the humidity levels in the environment, adjusting its operation to maintain desired settings without manual intervention. This smart technology not only conserves energy but also ensures optimal performance.

In addition to its dehumidification function, the Sterling dryer is equipped with a built-in air filtration system that captures dust and allergens, contributing to overall indoor air quality. The easy-to-clean filters are designed for durability, ensuring that the unit remains functional and effective over time.

Another notable characteristic of the Sterling Plumbing Dehumidifying Dryer is its user-friendly interface. The control panel is designed to be intuitive, allowing users to easily set their preferred humidity levels and adjust operation modes. With options for continuous drainage, users can also opt to run the unit without worrying about emptying the water tank frequently.

Overall, the Sterling Plumbing 150, 225, 90 Cabinet Series Dehumidifying Dryer is a powerful, efficient, and reliable moisture management solution. With its blend of advanced technology, user-friendly features, and robust design, it is an essential appliance for anyone looking to improve indoor air quality and protect their space from the damaging effects of excess moisture.