OPERATION
OPERATING PROCEDURES | COLD WEATHER OPERATION |
•Observe all safety precautions given in this manual. If the RV06 is to be used during cold weather, preheat
• Refer to the applicable manual for the tool connect- | the hydraulic fluid at low engine speed. When using the | |
normally recommended fluids, fluid temperature should | ||
ed to the RV06. | ||
be at or above 50 °F/10 °C (400 ssu/82 centistokes) be- | ||
• Activate the parent circuit to provide power to the in- | ||
fore use. | ||
tensifier. Pressure will now be available at the pres- | Damage to the hydraulic system or RV06 can result | |
sure port of the RV06. | ||
from use with fluid that is too viscous or thick. | ||
• To advance the ram of the connected tool, press the | ||
| ||
forward end of the rocker arm. |
| |
• When the crimp or cut is complete, release the rock- |
| |
er arm and the RV06 will go to a “neutral” or “hold” |
| |
position. The tool ram will remain stationary. |
| |
• To retract the tool ram, press the rear of the rocker |
| |
arm. If the RV06 is connected to a |
| |
tool, the ram will retract under power. If the tool is |
| |
| ||
slowly due to its spring return. |
|
RV06 User Manual ◄ 11