OPERATION
OPERATING PROCEDURES | COLD WEATHER OPERATION | 
•Observe all safety precautions given in this manual. If the RV06 is to be used during cold weather, preheat
• Refer to the applicable manual for the tool connect-  | the hydraulic fluid at low engine speed. When using the  | |
normally recommended fluids, fluid temperature should  | ||
ed to the RV06.  | ||
be at or above 50 °F/10 °C (400 ssu/82 centistokes) be-  | ||
• Activate the parent circuit to provide power to the in-  | ||
fore use.  | ||
tensifier. Pressure will now be available at the pres-  | Damage to the hydraulic system or RV06 can result  | |
sure port of the RV06.  | ||
from use with fluid that is too viscous or thick.  | ||
• To advance the ram of the connected tool, press the  | ||
  | ||
forward end of the rocker arm.  | 
  | |
• When the crimp or cut is complete, release the rock-  | 
  | |
er arm and the RV06 will go to a “neutral” or “hold”  | 
  | |
position. The tool ram will remain stationary.  | 
  | |
• To retract the tool ram, press the rear of the rocker  | 
  | |
arm. If the RV06 is connected to a   | 
  | |
tool, the ram will retract under power. If the tool is  | 
  | |
  | ||
slowly due to its spring return.  | 
  | 
RV06 User Manual ◄ 11